Barbacoa & Carnitas Don Chepe Inc.
May 27, 2026 · Pass
😇clean
- official resultPass
- resultPass
- inspection typeLicense Re-Inspection
- failed findings5
- critical findings0
Failed findings
-
Contamination Prevented During Food Preparation, Storage & DisplayInspector note: 3-307.11: OBSERVED PEELING PAINT ON DRAINAGE CEILING TRACKS IN WALK IN COOLER. INSTRUCTED TO REMOVE PEELING PAINT TO PREVENT PEELING PAINT FROM CONTAMINATING FOOD IN WALK IN COOLER AND SMOOTHLY REPAINT DRAINAGE CEILING TRACKS IN WALK IN COOLER. OBSERVED NO RIGHT SPLASH GUARD ON HANDWASHING SINK IN BEVERAGE STATION. INSTRUCTED TO INSTALL RIGHT SPLASH GUARD ON HANDWASHING SINK IN BEVERAGE STATION TO PREVENT CONTAMINATION OF EQUIPMENT TO THE RIGHT OF SAID HANDWASHING SINK.
-
bathroom / plumbing issuesOfficial wording: Plumbing Installed; Proper Backflow DevicesInspector note: 4-301.16: OBSERVED NO PREP/DUMP SINK IN BEVERAGE STATION. INSTRUCTED TO INSTALL A PREP/DUMP SINK IN BEVERAGE STATION A MINIMUM OF ONE SINK USED FOR FOOD PREPARATION, OBTAINING WATER AND DISCARDING LIQUID WASTE IS REQUIRED IN ANY PREPARATION AREA. • 5-204.12: UNABLE TO LOCATE BACKFLOW PREVENTION DEVICE ON UTILITY SINK. INSTRUCTED TO INSTALL BACKFLOW PREVENTION DEVICE ON UTILITY SINK SO THAT IT SHALL BE LOCATED SO THAT IT MAY BE SERVICED AND MAINTAINED.
-
floors, walls, or ceilings grimyOfficial wording: Physical Facilities Installed, Maintained & CleanInspector note: 6-501.11: OBSERVED STAINED CEILING TILES IN FRONT PREP AREA. OBSERVED PEELING PAINT ON DUCTS IN FRONT PREP AREA. INSTRUCTED TO REPLACE ALL STAINED CEILING TILES IN FRONT PREP AREA. INSTRUCTED TO REMOVE PEELING PAINT AND SMOOTHLY REPAINT DUCTS IN FRONT PREP AREA FOR EASE OF CLEANABILITY AND MAINTAIN. OBSERVED PEELING CEILING PAINT IN MIDDLE PREP AREA WITH COOKING EQUIPMENT NEAR WINDOW. INSTRUCTED TO REMOVE PEELING PAINT AND SMOOTHLY REPAINT CEILING IN SAID AREA AND MAINTAIN.
-
Adequate Ventilation & Lighting; Designated Areas UsedInspector note: 6-304.11: OBSERVED NO MECHANICAL VENTILATION INSTALLED IN EMPLOYEE ALL GENDER WASHROOM. INSTRUCTED TO INSTALL MECHANICAL VENTILATION OF SUFFICIENT CAPACITY IN EMPLOYEE ALL GENDER WASHROOM. OBSERVED NON WORKING SMALL HOOD INSTALLED ABOVE COOKING EQUIPMENT INSTALLED ON SOUTH WALL NEAR WINDOW IN MIDDLE PREP AREA. INSTRUCTED TO REPAIR OR REPLACE NON WORKING MECHANICAL VENTILATION(SMALL HOOD INSTALLED ON SOUTH WALL) OF SUFFICIENT CAPACITY ABOVE COOKING EQUIPMENT NEAR WINDOW IN MIDDLE PREP AREA.
-
allergen training missingOfficial wording: Allergen Training As RequiredInspector note: 2-102.13: AT TIME OF INSPECTION FACILITY PROVIDED NO ALLERGEN AWARENESS TRAINING CERTIFICATES FOR EMPLOYEES WITH CITY OF CHICAGO FOOD SERVICE SANITATION CERTIFICATES. INSTRUCTED TO PROVIDE PROOF OF ALLERGEN TRAINING FOR ALL EMPLOYEES WITH CITY OF CHICAGO FOOD SERVICE SANITATION CERTIFICATES.
What changed since the previous inspection?
Compared with Fail on May 19, 2026: 5 findings recurred. 3 previous findings did not recur.
Browse this restaurant's inspections
More restaurants in Brighton Park
About this record
This record comes from Chicago Department of Public Health. Cooked keeps the official result and wording separate from its plain-English explanation so you can verify what the inspector actually published.
Source: Chicago Data Portal.