I 57 Smokehouse

December 15, 2010 · Pass
😇clean
  • official resultPass
  • resultPass
  • inspection typeComplaint
  • failed findings6
  • critical findings0

← Back to the current restaurant page

Failed findings

  • Food And Non-Food Contact Surfaces Properly Designed, Constructed And Maintained
    Inspector note: All food and non-food contact equipment and utensils shall be smooth, easily cleanable, and durable, and shall be in good repair. REPAIR DAMAGED GASKET ON 2-DOOR REACH-IN COOLER DOOR. PAINT SHELVES UNDER FRONT COUNTER.
    code 32
  • food prep surfaces dirty
    Official wording: Food And Non-Food Contact Equipment Utensils Clean, Free Of Abrasive Detergents
    Inspector note: All food and non-food contact surfaces of equipment and all food storage utensils shall be thoroughly cleaned and sanitized daily. CLEAN INTERIOR AND EXTERIOR OF VENTILATION HOOD.
    code 33
  • Floors: Constructed Per Code, Cleaned, Good Repair, Coving Installed, Dust-Less Cleaning Methods Used
    Inspector note: The floors shall be constructed per code, be smooth and easily cleaned, and be kept clean and in good repair. FLOORS NEED CLEANING UNDER ALL EQUIPMENT ALONG WALLS AND IN ALL CORNERS IN FURNACE ROOM, STORAGE, WASHROOM AND PREP AREAS.
    code 34
  • Walls, Ceilings, Attached Equipment Constructed Per Code: Good Repair, Surfaces Clean And Dust-Less Cleaning Methods
    Inspector note: The walls and ceilings shall be in good repair and easily cleaned. REPLACE STAINED CEILING TILES IN ALL AREAS. REPLACE MISSING BASEBOARDS IN ALL AREAS. CLEAN ALL CEILING VENTS.
    code 35
  • thermometers missing
    Official wording: Lighting: Required Minimum Foot-Candles Of Light Provided, Fixtures Shielded
    Inspector note: Shielding to protect against broken glass falling into food shall be provided for all artificial lighting sources in preparation, service, and display facilities. REPLACE MISSING LIGHT SHIELD AND CLEAN SOILED LIGHT SHIELDS IN PREP AREA.
    code 36
  • pests in the house
    Official wording: Ventilation: Rooms And Equipment Vented As Required: Plumbing: Installed And Maintained
    Inspector note: INSTALL BACK FLOW DEVICE ON UTILITY SINK.
    code 38

What changed since the previous inspection?

Compared with Pass on January 21, 2010: 2 findings appeared for the first time. 4 findings recurred.

Browse this restaurant's inspections

About this record

This record comes from Chicago Department of Public Health. Cooked keeps the official result and wording separate from its plain-English explanation so you can verify what the inspector actually published.

Source: Chicago Data Portal.

official city health-inspection data · no account, no sign-up