Irene's

September 23, 2022 · Fail
🪳cooked
  • official resultFail
  • resultFail
  • inspection typeLicense
  • failed findings7
  • critical findings1

← Back to the current restaurant page

Failed findings

  • sick-employee policy not followedcritical
    Official wording: Management, Food Employee And Conditional Employee; Knowledge, Responsibilities And Reporting
    Inspector note: OBSERVED NO WRITTEN EMPLOYEE HEALTH POLICY ON THE PREMISES. MANAGEMENT INSTRUCTED TO PROVIDE A SIGNED EMPLOYEE HEALTH POLICY FOR EACH EMPLOYEE. PRIORITY FOUNDATION VIOLATION 7-38-010.
    code 3Priority
  • surfaces / setup not up to code
    Official wording: Food & Non-Food Contact Surfaces Cleanable, Properly Designed, Constructed & Used
    Inspector note: OBSERVED STAINED CUTTING BOARD ON TOP OF THE 3-DOOR PREP LINE COOLER.INSTRUCTED TO RESURFACE OR REPLACE THE CUTTING BOARD.
    code 47
  • Warewashing Facilities: Installed, Maintained & Used; Test Strips
    Inspector note: OBSERVED MISSING SINK STOPPERS FOR THE DISHWASHING 3-COMPARTMENT SINK.INSTRUCTED TO PROVIDE AND MAINTAIN 3 ADEQUATE WORKING SINK STOPPERS.
    code 48
  • bathroom / plumbing issues
    Official wording: Plumbing Installed; Proper Backflow Devices
    Inspector note: BACKFLOW PREVENTION DEVICES NOT LOCATED AT ICE MACHINE, HOT WATER DISPENSER UNIT.MUST INSTALL SO BACKFLOW PREVENTION DEVICES MAY BE LOCATED TO BE SERVICED AND MAINTAINED.
    code 51
  • Sewage & Waste Water Properly Disposed
    Inspector note: OBSERVED WASTE WATER BACKING-UP AT THE DISHWASHING 3-COMPARTMENT SINK WHEN WATER IS RELEASED FROM MIDDLE COMPARTMENT,WATER BACKS UP INTO LEFT AND RIGHT COMPARTMENTS OF THE DISHWASHING 3-COMPARTMENT SINK AND WATER SLOW DRAINING.INSTRUCTED TO REPAIR PLUMBING ISSUE AND MAINTAIN AS REQUIRED. PRIORITY VIOLATION 7-38-030 (C).
    code 52
  • Toilet Facilities: Properly Constructed, Supplied, & Cleaned
    Inspector note: A TOILET ROOM USED BY FEMALES SHALL BE PROVIDED WITH A COVERED RECEPTACLE FOR SANITARY NAPKINS.
    code 53
  • Adequate Ventilation & Lighting; Designated Areas Used
    Inspector note: OBSERVED NO VENTILATION OVER ELECTRIC OVEN IN REAR PREP/DISHWASHING AREA.INSTRUCTED MANAGEMENT TO PROVIDE VENTILATION OVER OVEN OR PROVIDE THAT THE OVEN IS 7.5 KILLOWATTS OR BELOW. • OBSERVED MECHANICAL VENTILATION IN WASHROOMS NOT WORKING.MUST REPAIR AND MAINTAIN AT ALL TIMES.
    code 56

What changed since the previous inspection?

Compared with Not Ready on May 4, 2022: 7 findings appeared for the first time.

Browse this restaurant's inspections

About this record

This record comes from Chicago Department of Public Health. Cooked keeps the official result and wording separate from its plain-English explanation so you can verify what the inspector actually published.

Source: Chicago Data Portal.

official city health-inspection data · no account, no sign-up