Lokal

August 30, 2017 · Pass
😇clean
  • official resultPass
  • resultPass
  • inspection typeCanvass
  • failed findings7
  • critical findings0

← Back to the current restaurant page

Failed findings

  • Food And Non-Food Contact Surfaces Properly Designed, Constructed And Maintained
    Inspector note: MUST DISCONTINUE THE USE OF ALUMINUM FOIL ON KITCHEN EQUIPMENT. REPAIR DOOR GASKET ON 3-DOOR PREP COOLER IN PREP AREA. REPLACE CUTTING BOARD ON PREP COOLER, BLACK GROOVES PRESENT. REMOVE RUST FROM STORAGE RACKS ON 2-DOOR TRUE COOLER IN PREP AREA. DEFROST ALL DEEP FREEZERS IN BASEMENT, EXCESSIVE ICE ACCUMULATION PRESENT. INSTRUCTED TO MAINTAIN ALL.
    code 32
  • food prep surfaces dirty
    Official wording: Food And Non-Food Contact Equipment Utensils Clean, Free Of Abrasive Detergents
    Inspector note: MUST DETAIL CLEAN DRIED FOOD DEBRIS FROM GRILL AND STOVE IN PREP AREA. CLEAN DEBRIS FROM SODA NOZZLES AT FRONT BAR. INSTRUCTED TO MAINTAIN.
    code 33
  • Floors: Constructed Per Code, Cleaned, Good Repair, Coving Installed, Dust-Less Cleaning Methods Used
    Inspector note: DETAIL CLEAN DEBRIS OR DIRT FROM FLOORS IN THE FOLLOWING AREAS; STAFF TOILET ROOM, DRY STORAGE ROOM, SHOWER ROOM IN BASEMENT, AND THROUGHOUT BASEMENT. INSTRUCTED TO MAINTAIN.
    code 34
  • Walls, Ceilings, Attached Equipment Constructed Per Code: Good Repair, Surfaces Clean And Dust-Less Cleaning Methods
    Inspector note: MUST CLEAN GREASE ACCUMULATION FROM HOOD AND FILTERS. CLEAN EXCESSIVE DUST ACCUMULATION FROM CEILING VENTS IN MENS AND WOMENS TOILET ROOMS IN THE BASEMENT; STAFF TOILET ROOM; AND WALL VENT IN REAR DINING AREA. ALSO, REPAIR DAMAGED LOWER WALL IN WAIT/COFFEE STATION. INSTRUCTED TO MAINTAIN ALL.
    code 35
  • thermometers missing
    Official wording: Lighting: Required Minimum Foot-Candles Of Light Provided, Fixtures Shielded
    Inspector note: MUST REPLACE BURNED OUT LIGHTS IN THE PREP AREA. ALSO, CLEAN UNKNOWN DEBRIS FROM LIGHT SHIELDS IN PREP AND DRY STORAGE AREAS. INSTRUCTED TO MAINTAIN.
    code 36
  • pests in the house
    Official wording: Ventilation: Rooms And Equipment Vented As Required: Plumbing: Installed And Maintained
    Inspector note: MUST REPAIR LEAKY PIPE UNDERNEATH EXPOSED HAND SINK AND 3-COMP SINK IN PREP AREA. REPAIR SLOW DRAIN IN HAND SINK IN WOMENS TOILET ROOM IN BASEMENT. INSTRUCTED TO MAINTAIN ALL.
    code 38
  • grimy wiping cloths
    Official wording: Premises Maintained Free Of Litter, Unnecessary Articles, Cleaning Equipment Properly Stored
    Inspector note: MUST REMOVE EXCESSIVE CLUTTER (TOWELS, APRONS, ETC.)FROM STAIRCASE LEADING TO UPSTAIRS APARTMENT TO PREVENT RODENT HARBORAGE, AND MAINTAIN.
    code 41

What changed since the previous inspection?

Compared with No Entry on August 21, 2017: 7 findings appeared for the first time.

Browse this restaurant's inspections

About this record

This record comes from Chicago Department of Public Health. Cooked keeps the official result and wording separate from its plain-English explanation so you can verify what the inspector actually published.

Source: Chicago Data Portal.

official city health-inspection data · no account, no sign-up