✕
Lp's T.A.P House
November 8, 2016 · Fail
🪳cooked
- official resultFail
- resultFail
- inspection typeCanvass
- failed findings10
- critical findings1
Failed findings
-
handwashing sink issuescriticalOfficial wording: Sanitizing Rinse For Equipment And Utensils: Clean, Proper Temperature, Concentration, Exposure TimeInspector note: OBSERVED A LOW TEMPERATURE DISH MACHINE NOT IN USE AT THIS TIME.OBSERVED DISH MACHINE SANITIZING FINAL RINSE AT 0.P.P.M. INSTRUCTED TO USE 3- COMPARTMENT SINK TO WASH,RINSE AND SANITIZE MULTIUSE UTENSILS.MUST HAVE DISH MACHINE FINAL RINSE AT 50 P.P.M.A HELD FOR INSPECTION TAG PLACED ON UNIT.ONCE REPAIRED FAX LETTER TO (312)746-4240 WHEN READY.(CRITICAL 7-38-030)
-
toxic items stored near foodOfficial wording: No Evidence Of Rodent Or Insect Outer Openings Protected/Rodent Proofed, A Written Log Shall Be Maintained Available To The InspectorsInspector note: OBSERVED EVIDENCE OF LIVE ROACHES CRAWLING 9-ON FLOOR UNDER 3- DOOR REACH IN COOLER AND LOWER WALL BASE,2-ON LOWER WALL BASE UNDER 3- COMPARTMENT SINK IN REAR PREP AREA AND 2-ON FLOOR UNDER CHEST FREEZER IN BASEMENT.6- LIVE SMALL FLIES FLYING AROUND IN 2ND FL. LARGE BAR AREA.ALSO REAR RIGHT SIDE OF DOUBLE DOOR HAS A APPX. "3/4" ALONG BOTTOM.MUST RODENT PROOF DOOR.RECOMMENDED TO HAVE A PEST CONTROL OPERATOR TO SERVICE PREMISES ON OR AFTER 11/8/16.(SERIOUS 7-38-020)
-
Clean Multi-Use Utensils And Single Service Articles Properly Stored: No Reuse Of Single Service ArticlesInspector note: MUST INVERT MULTIUSE UTENSILS ON LOWER SHELF OF PREP TABLE.
-
Food And Non-Food Contact Surfaces Properly Designed, Constructed And MaintainedInspector note: MUST APPLY A SEALANT OR PAINT RAW WOOD SHELVING UNIT IN BASEMENT ALONG WALL OF BEER WALK IN COOLER.MUST REMOVE RUST FROM SHELVING UNITS IN BEER WALK IN COOLER .MUST REPAIR OR REPLACE BROKEN LID ON ICE BIN IN 1ST FL. SMALL BAR AREA.
-
food prep surfaces dirtyOfficial wording: Food And Non-Food Contact Equipment Utensils Clean, Free Of Abrasive DetergentsInspector note: MUST CLEAN EXCESSIVE GREASE AND FOOD DEBRI FROM MICROWAVE,FRYER CABINET,GRILL TABLE,WHEEL BASES OF EQUIPMENT,INTERIOR PANEL OF 1ST FL. ICE MACHINE,PIPES OF COOKING EQUIPMENT,BASEMENT FOOD AND PAPER SHELVING UNITS,BEER WALK IN COOLER FAN GUARDS.
-
Floors: Constructed Per Code, Cleaned, Good Repair, Coving Installed, Dust-Less Cleaning Methods UsedInspector note: MUST CLEAN FOOD DEBRI AND GREASE FROM FLOOR UNDER,AROUND,ALONG WALL BASES IN PREP AREA AND ALL BAR AREAS,FLOOR DRAINS.MUST SEAL GAP IN BETWEEN FLOOR AND WALL BASE IN 1ST FL. WOMEN'S TOILETROOM
-
Walls, Ceilings, Attached Equipment Constructed Per Code: Good Repair, Surfaces Clean And Dust-Less Cleaning MethodsInspector note: MUST CLEAN DIRT BUILD UP FROM WALLS AND CEILING IN BEER WALK IN COOLER,LOWER WALLS IN ALL BAR AREAS.MUST SEAL GAP IN LOWER WALL BASE UNDER 3- COMP SINK IN DISH WASHING AREA,ALL OPENINGS AROUND PIPES LEADING INTO WALL IN PREP AREA.MUST CLEAN GREASE FROM FILTERS AT HOOD OF COOKING EQUIPMENT.MUST REPAIR OR REPLACE MISSING WALL BASE IN 1ST FL. WOMEN'S 1ST. STALL BEHIND TOILET.,HOLE IN CEILING IN DISH WASHING AREA
-
thermometers missingOfficial wording: Lighting: Required Minimum Foot-Candles Of Light Provided, Fixtures ShieldedInspector note: MUST REPLACE MISSING LIGHT SHIELD IN PREP AREA
-
pests in the houseOfficial wording: Ventilation: Rooms And Equipment Vented As Required: Plumbing: Installed And MaintainedInspector note: MUST PROVIDE SINK STOPPERS FOR 3- COMP SINK IN DISH WASHING AREA
-
grimy wiping clothsOfficial wording: Premises Maintained Free Of Litter, Unnecessary Articles, Cleaning Equipment Properly StoredInspector note: MUST REMOVE,ELEVATE AND ORGANIZE ARTICLES OFF OF FLOOR AND AWAY FROM WALLS IN BASEMENT
What changed since the previous inspection?
Compared with Pass on January 21, 2016: 3 findings appeared for the first time. 7 findings recurred. 1 previous finding did not recur.
Browse this restaurant's inspections
More restaurants in Lincoln Park
About this record
This record comes from Chicago Department of Public Health. Cooked keeps the official result and wording separate from its plain-English explanation so you can verify what the inspector actually published.
Source: Chicago Data Portal.