Macaroni Grill (T3-K2)

May 16, 2017 · Fail
🪳cooked
  • official resultFail
  • resultFail
  • inspection typeCanvass
  • failed findings6
  • critical findings0

← Back to the current restaurant page

Failed findings

  • toxic items stored near food
    Official wording: No Evidence Of Rodent Or Insect Outer Openings Protected/Rodent Proofed, A Written Log Shall Be Maintained Available To The Inspectors
    Inspector note: Observed 45 mouse droppings in facility along windows behind the benches for seating. Also found 20 ants in the kitchen near the front exposed handsink. Instructed facility to remove all evidence of pests and pests and maintain. Recommended to contact a licensed pest control provider for service. Serious violation 7-38-020.
    code 18
  • Food And Non-Food Contact Surfaces Properly Designed, Constructed And Maintained
    Inspector note: Observed torn refrigeration gaskets on the right door of the protein 2 door cooler and on the left door of the reach in 2 door cheese cooler. Instructed facility to replace and maintain.
    code 32
  • food prep surfaces dirty
    Official wording: Food And Non-Food Contact Equipment Utensils Clean, Free Of Abrasive Detergents
    Inspector note: Observed the pizza cooler near the impinger oven to have standing water and food debris in the bottom and in the tracks under the drawers. Instructed facility to clean and maintain.
    code 33
  • Floors: Constructed Per Code, Cleaned, Good Repair, Coving Installed, Dust-Less Cleaning Methods Used
    Inspector note: Observed dirt and food debris on the floors throughout the prep areas along wall bases, under and around equipment, and near dish machine. Instructed facility to clean all and maintain.
    code 34
  • Walls, Ceilings, Attached Equipment Constructed Per Code: Good Repair, Surfaces Clean And Dust-Less Cleaning Methods
    Inspector note: Observed the ceilings in the prep areas to be dirty and stained with grease accumulation. Instructed facility to clean and maintain. Observed the wall by the dish machine and the wall behind the front prep coolers to be dirty. Instructed facility to clean and maintain.
    code 35
  • pests in the house
    Official wording: Ventilation: Rooms And Equipment Vented As Required: Plumbing: Installed And Maintained
    Inspector note: Observed a small leak at the drain pipe below the front exposed handsink. Instructed facility to repair.
    code 38

What changed since the previous inspection?

Compared with Pass w/ Conditions on December 16, 2016: 3 findings appeared for the first time. 3 findings recurred. 1 previous finding did not recur.