?

Marathon Mart

April 12, 2017 · No Entry
🫥not rated
  • official resultNo Entry
  • inspection typeCanvass Re-Inspection
  • failed findings10
  • critical findings2

← Back to the current restaurant page

Failed findings

  • food from a questionable sourcecritical
    Official wording: Adequate Number, Convenient, Accessible, Designed, And Maintained
    Inspector note: Inspector Comments: OBSERVED NO HANDWASHING SINK IN THE WASHROOM. MANAGEMENT INSTRUCTED TO INSTALL A HANDWASHING SINK IN THE WASHROOM AND SUPPLY IT WITH HOT AND COLD RUNNING WATER AND SOAP AND PAPER TOWELS. MUST ALSO INSTALL AN EXPOSED HANDWASHING SINK ADJACENT TO THE 3 COMPARTMENT SINK. CRITICAL VIOLATION 7-38-030
    code 11Priority
  • water/temperature at the sink offcritical
    Official wording: Water Source: Safe, Hot & Cold Under City Pressure
    Inspector note: Inspector Comments: NO HOT WATER PROVIDED THROUGHOUT THE PREMISES. MANAGEMENT INSTRUCTED TO PROVIDE HOT WATER ABOVE 110F FOR PROPER WASHING OF UTENSILS. CRITICAL VIOLATION 7-38-030
    code 9Priority
  • toxic items stored near food
    Official wording: No Evidence Of Rodent Or Insect Outer Openings Protected/Rodent Proofed, A Written Log Shall Be Maintained Available To The Inspectors
    Inspector note: Inspector Comments: OBSERVED EVIDENCE OF RODENT ACTIVITY ON THE PREMISES AND BUILDING NOT RODENT PROOF. OBSERVED APPROXIMATELY 80 MOUSE DROPPINGS ON THE FLOOR, ON THE ELECTRICAL BOXES, NEXT TO THE ICE FREEZER, AND IN THE STORAGE ROOM AROUND THE BOXES OF BEVERAGES. ALSO OBSERVED A DEAD MOUSE ON THE GLUEBOARD NEXT TO THE ICE FREEZER. MANAGEMENT INSTRUCTED TO CLEAN AND REMOVE ALL DROPPINGS. ALSO, OBSERVED THE BUILDING NOT RODENT PROOFED. THERE IS A 1/2" GAP BETWEEN THE DOOR FRAME OF THE FRONT ENTRANCE DOOR AND THE CONCRETE WALL. MANAGEMENT INSTRUCTED TO SEAL THE WALL TO PREVENT ENTRY OF RODENTS. ALSO, OBSERVED OPEN RODENT BAIT/POISON STORED UNDERNEATH THE BEVERAGE COOLERS. MANAGEMENT INSTRUCTED TO REMOVE. ADDITIONAL PEST CONTROL SERVICE IS NEEDED TO ELIMINATE OR MINIMIZE THE PEST ACTIVITY. SERIOUS VIOLATION 7-38-020
    code 18
  • Dish Washing Facilities: Properly Designed, Constructed, Maintained, Installed, Located And Operated
    Inspector note: Inspector Comments: OBSERVED THE 3 COMPARTMENT SINK IMPROPERLY INSTALLED IN THE WASHROOM AND IS BACKING UP WITH WATER WHEN THE WATER IS RUN. MANAGEMENT INSTRUCTED TO REMOVE THE 3 COMPARTMENT SINK FROM THE WASHROOM AND REINSTALL IT WITH A GREASE TRAP AND A FAUCET THAT WILL REACH ALL 3 COMPARTMENTS WITHOUT ANY WASTE WATER BACKUP. SERIOUS VIOLATION 7-38-030
    code 24
  • food prep surfaces dirty
    Official wording: Food And Non-Food Contact Equipment Utensils Clean, Free Of Abrasive Detergents
    Inspector note: Inspector Comments: CLEAN THE FOLLOWING ITEMS: 3 COMPARTMENT SINK, ALL STORAGE SHELVES, ALL REACH-IN COOLERS
    code 33
  • Floors: Constructed Per Code, Cleaned, Good Repair, Coving Installed, Dust-Less Cleaning Methods Used
    Inspector note: Inspector Comments: CLEAN THE FLOOR THROUGHOUT ESPECIALLY ALONG WALLS, AND UNDER EQUIPMENT. REPLACE THE BROKEN FLOOR TILES IN FRONT OF THE REACH-IN COOLERS.
    code 34
  • Walls, Ceilings, Attached Equipment Constructed Per Code: Good Repair, Surfaces Clean And Dust-Less Cleaning Methods
    Inspector note: Inspector Comments: REPLACE THE STAINED CEILING TILES IN THE DISPLAY AREA. CLEAN THE GLASS WINDOWS AND WINDOW SILLS THROUGHOUT
    code 35
  • thermometers missing
    Official wording: Lighting: Required Minimum Foot-Candles Of Light Provided, Fixtures Shielded
    Inspector note: Inspector Comments: REPLACE THE LIGHT THAT IS OUT IN THE DISPLAY AREA
    code 36
  • pests in the house
    Official wording: Ventilation: Rooms And Equipment Vented As Required: Plumbing: Installed And Maintained
    Inspector note: Inspector Comments: REPAIR THE LEAK AT THE 3 COMPARTMENT SINK. MUST PROVIDE 3 SINK STOPPERS FOR THE 3 COMPARTMENT SINK
    code 38
  • Refrigeration And Metal Stem Thermometers Provided And Conspicuous
    Inspector note: Inspector Comments: NO THERMOMETER PROVIDED INSIDE OF THE MILK COOLER. MUST PROVIDE AND MAINTAIN IT INSIDE.
    code 40

What changed since the previous inspection?

Compared with Fail on March 31, 2017: 10 findings recurred. 2 previous findings did not recur.

Browse this restaurant's inspections

About this record

This record comes from Chicago Department of Public Health. Cooked keeps the official result and wording separate from its plain-English explanation so you can verify what the inspector actually published.

Source: Chicago Data Portal.

official city health-inspection data · no account, no sign-up