July 18, 2011 · Pass
😇clean
  • official resultPass
  • resultPass
  • inspection typeCanvass
  • failed findings5
  • critical findings0

← Back to the current restaurant page

Failed findings

  • Food And Non-Food Contact Surfaces Properly Designed, Constructed And Maintained
    Inspector note: CUTTING BOARDS WITH DEEP/ DARK GROOVES MUST BE REPLACED. METAL PLATE AT INTERIOR OF WALK-IN FREEZER DOOR MUST BE FIXED (PULLED OUT OF DOOR)-MUST ADDRESS. All food and non-food contact equipment and utensils shall be smooth, easily cleanable, and durable, and shall be in good repair.
    code 32
  • food prep surfaces dirty
    Official wording: Food And Non-Food Contact Equipment Utensils Clean, Free Of Abrasive Detergents
    Inspector note: LIGHT SHIELDS NEED CLEANING DUE TO DEBRIS/DUST BUILD-UP, MUST MAINTAIN CLEAN. All food and non-food contact surfaces of equipment and all food storage utensils shall be thoroughly cleaned and sanitized daily.
    code 33
  • Floors: Constructed Per Code, Cleaned, Good Repair, Coving Installed, Dust-Less Cleaning Methods Used
    Inspector note: FLOORS OF DRY STORAGE ROOM MUST BE KEPT CLEAN; FLOOR AT BAR AREA (EAST WALL-3RD FLOOR) NEED RE-GROUTING. The floors shall be constructed per code, be smooth and easily cleaned, and be kept clean and in good repair.
    code 34
  • Walls, Ceilings, Attached Equipment Constructed Per Code: Good Repair, Surfaces Clean And Dust-Less Cleaning Methods
    Inspector note: AN OPENING ON THE RIGHT WALL BELOW THE DISHMACHINE DRAINBOARD MUST BE SEALED & ANY WALL PANEL THAT'S PULLING AWAY FRON THE WALL MUST BE ADDRESSED (SAME AREA). DUST ACCUMULATING ON 2-CORNERS OF A WALL (LOWER LEVEL) OF A PREP AREA. The walls and ceilings shall be in good repair and easily cleaned.
    code 35
  • pests in the house
    Official wording: Ventilation: Rooms And Equipment Vented As Required: Plumbing: Installed And Maintained
    Inspector note: LEAK NOTED AT BOTTOM RIGHT SIDE OF 3-COMP SINK & AT BOTTOM PIPE OF A 1-COMP SINK IN LOWER LEVEL - MUST FIX. CONDENSATION WATER FROM 3-COOLERS ARE ACCUMULATING ON THE COOLER FLOORS, INSTRUCTED TO MONITOR/CLEAN COMPRESSORS. Ventilation: All plumbing fixtures, such as toilets, sinks, washbasins, etc., must be adequately trapped, vented, and re-vented and properly connected to the sewer in accordance with the plumbing chapter of the Municipal Code of Chicago and the Rules and Regulations of the Board of Health.
    code 38

What changed since the previous inspection?

Compared with Pass on May 20, 2010: 3 findings appeared for the first time. 2 findings recurred. 1 previous finding did not recur.