Rainbow Bubble Tea
June 15, 2023 · Fail
🪳cooked
- official resultFail
- resultFail
- inspection typeLicense
- failed findings7
- critical findings1
Failed findings
-
handwashing sink blocked or barecriticalOfficial wording: Adequate Handwashing Sinks Properly Supplied And AccessibleInspector note: MISSING HANDWASH SINK IN PREP AREA. INSTD TO PROVIDE AND MAINTAIN HANDWASH SINK WITH HOT/COLD RUNNING WATER UNDER CITY PRESSURE, SOAP AND HAND DRYING PROVISION. PRIORITY FOUNDATION 7-38-030(C)
-
surfaces not properly sanitizedOfficial wording: Food-Contact Surfaces: Cleaned & SanitizedInspector note: MISSING SANITIZER ON SITE TO PROPERLY WASH, RINSE AND SANITIZE. INSTD TO PROVIDE AND MAINTAIN ON SITE AT ALL TIMES. PRIORITY VIOLATION 7-38-005
-
thermometers missingOfficial wording: Thermometers Provided & AccurateInspector note: MISSING FOOD TEMPERATURE MEASURING DEVICE. INSTD TO PROVIDE AND MAINTAIN SAME. PRIORITY FOUNDATION 7-38-005.
-
surfaces / setup not up to codeOfficial wording: Food & Non-Food Contact Surfaces Cleanable, Properly Designed, Constructed & UsedInspector note: RAW WOOD SURFACES THROUGH OUT PREP AREA. INSTD TO SEAL ALL RAW SO AS TO BE SMOOTH, EVEN, AND EASILY CLEANABLE SURFACE.
-
Warewashing Facilities: Installed, Maintained & Used; Test StripsInspector note: MISSING CHEMICAL TEST DEVICE FOR SANITIZING SOLUTION. INSTD TO PROVIDE AND MAINTAIN SAME. PRIORITY FOUNDATION 7-38-005.
-
bathroom / plumbing issuesOfficial wording: Plumbing Installed; Proper Backflow DevicesInspector note: MISSING BACKFLOW PREVENTION DEVICE AT ICE MACHINE. INSTD TO PROVIDE AND MAINTAIN SAME. • MISSING PREP SINK ON SITE. INSTD TO INSTALL PREP SINK AND MAINTAIN WITH HOT/COLD RUNNING WATER UNDER CITY PRESSURE.
-
Sewage & Waste Water Properly DisposedInspector note: MISSING GREASE TRAP AT 3-COMPARTMENT SINK. INSTD TO INSTALL AND MAINTAIN SAME.
Browse this restaurant's inspections
More restaurants in West Elsdon
About this record
This record comes from Chicago Department of Public Health. Cooked keeps the official result and wording separate from its plain-English explanation so you can verify what the inspector actually published.
Source: Chicago Data Portal.