✕
Tempo Cafe
January 4, 2010 · Fail
🪳cooked
- official resultFail
- resultFail
- inspection typeCanvass
- failed findings11
- critical findings0
Failed findings
-
toxic items stored near foodOfficial wording: No Evidence Of Rodent Or Insect Outer Openings Protected/Rodent Proofed, A Written Log Shall Be Maintained Available To The InspectorsInspector note: All necessary control measures shall be used to effectively minimize or eliminate the presence of rodents, roaches, and other vermin and insects on the premises of all food establishments, in food-transporting vehicles, and in vending machines. Front patio door not rodent proofed. Basement rear door not rodent proofed. Must seal and maintain all outer openings.
-
Outside Garbage Waste Grease And Storage Area; Clean, Rodent Proof, All Containers CoveredInspector note: The area outside of the establishment used for the storage of garbage shall be clean at all times and shall not constitute a nuisance. Outside garbage area not maintained. Must clean all areas to remove grease and food debris. Must close all dumpsters. Must clean and maintain at all times.
-
Food And Non-Food Contact Surfaces Properly Designed, Constructed And MaintainedInspector note: All food and non-food contact equipment and utensils shall be smooth, easily cleanable, and durable, and shall be in good repair. All cutting boards in need of replacing due to being worn and stained.
-
food prep surfaces dirtyOfficial wording: Food And Non-Food Contact Equipment Utensils Clean, Free Of Abrasive DetergentsInspector note: All food and non-food contact surfaces of equipment and all food storage utensils shall be thoroughly cleaned and sanitized daily. All utensils shall be thoroughly cleaned and sanitized after each usage. The following equipment in need of cleaning: all cooking equipment, sinks, soda box shelves, interior of reach-in and dish machine are. Must clean and maintain.
-
Floors: Constructed Per Code, Cleaned, Good Repair, Coving Installed, Dust-Less Cleaning Methods UsedInspector note: The floors shall be constructed per code, be smooth and easily cleaned, and be kept clean and in good repair. All floors through out in need of cleaning to remove build-up. Floor area at stoves in need of regrouting. Must correct and maintain.
-
Walls, Ceilings, Attached Equipment Constructed Per Code: Good Repair, Surfaces Clean And Dust-Less Cleaning MethodsInspector note: The walls and ceilings shall be in good repair and easily cleaned. Use dustless cleaning methods. All wall in need of cleaning to remove food splatters. Wall in basement storage area in need of repair of all broken tiles. Must correct and maintain.
-
thermometers missingOfficial wording: Lighting: Required Minimum Foot-Candles Of Light Provided, Fixtures ShieldedInspector note: All rooms in which food or drink is prepared, or in which utensils are washed, shall be lighted so that a minimum of 50-foot candles of light is available on all work surfaces. Shielding to protect against broken glass falling into food shall be provided for all artificial lighting sources in preparation, service, and display facilities. lights in basement and 1st floior in need of proper shields. Must install and maintain.
-
food improperly labeledOfficial wording: Toilet Room Doors Self Closing: Dressing Rooms With Lockers Provided: Complete Separation From Living/Sleeping QuartersInspector note: None of the operations connected with food establishments shall be conducted in any room used as living or sleeping quarters. Toilet rooms shall be completely enclosed and shall be vented to the outside air or mechanically ventilated. Must install self-closing device to 2nd floor employee washroom.
-
pests in the houseOfficial wording: Ventilation: Rooms And Equipment Vented As Required: Plumbing: Installed And MaintainedInspector note: The flow of air discharged from kitchen fans shall always be through a duct to a point above the roofline. Ventilation: All plumbing fixtures, such as toilets, sinks, washbasins, etc., must be adequately trapped, vented, and re-vented and properly connected to the sewer in accordance with the plumbing chapter of the Municipal Code of Chicago and the Rules and Regulations of the Board of Health. Must correct leak at faucet at basement prep sink. Must install dipper well at ice cream section.
-
Linen: Clean And Soiled Properly StoredInspector note: Soiled and clean linens, coats, and aprons shall be properly stored All linen dirty and clean must be stored properly. must maintain.
-
grimy wiping clothsOfficial wording: Premises Maintained Free Of Litter, Unnecessary Articles, Cleaning Equipment Properly StoredInspector note: All parts of the food establishment and all parts of the property used in connection with the operation of the establishment shall be kept neat and clean and should not produce any offensive odors. Cleaning equipment shall be properly stored away from food, utensils, equipment, and clean linens. All unnecessary clutter in basement storage area must be removed. Must maintain.
Browse this restaurant's inspections
More restaurants in Near North Side
About this record
This record comes from Chicago Department of Public Health. Cooked keeps the official result and wording separate from its plain-English explanation so you can verify what the inspector actually published.
Source: Chicago Data Portal.