✓
The Little Corner Snack Shop
May 3, 2017 · Pass
😇clean
- official resultPass
- resultPass
- inspection typeCanvass Re-Inspection
- failed findings6
- critical findings0
Failed findings
-
Food And Non-Food Contact Surfaces Properly Designed, Constructed And MaintainedInspector note: WASTE LINE FROM COOLER DRIPPING AT THIRD COMPARTMENT SINK.A WASTE LINE MUST BE PROPERLY CONNECTED SUCH THAT IT DRAINS DIRECTLY INTO A FLOOR DRAIN. EXCESS DUCT TAPE ON SHELF BETWEEN THE DISH MACHINE AND METAL SHELF. NEED TO REMOVE DUCT TAPE AND PROVIDE A SPLASH GUARD WITH A SMOOTH, CLEANABLE AND NON-ABSORBENT SURFACE.DUCT TAPE IS PROHIBITED. NO HANDLE PROVIDED AT WHITE REACH-IN FREEZER,DOOR IS HELD WITH A LONG ELASTIC ATTACHED TO STORAGE SHELF.RUBBER GASKET INSIDE THE DOOR IS BROKEN NEED TO REPLACE,AT SAME UNIT. BROKEN AND GRIMED PLASTIC CURTAINS AT INTERIOR OF WALK-IN COOLER NEED TO BE REPLACE,SURFACE MUST BE SMOOTH,CLEANABLE AND NON-ABSORBENT SURFACE
-
food prep surfaces dirtyOfficial wording: Food And Non-Food Contact Equipment Utensils Clean, Free Of Abrasive DetergentsInspector note: EXCESS GREASE INSIDE THE DEEP FRYER,AND EXCESS BURNED FOOD INSIDE THE OVEN. GREASE ON FILTERS AND HOOD,ALSO ON PIPES BEHIND AND UNDER COOKING EQUIPMENT. NEED TO CLEAN AND MAINTAIN. NEED TO REMOVE EXCESS ICE BUILD-UP INSIDE THE UNIT.KEEP IT CLEAN.
-
Floors: Constructed Per Code, Cleaned, Good Repair, Coving Installed, Dust-Less Cleaning Methods UsedInspector note: MISSING ,BROKEN, UNEVEN FLOOR TILES AND CEMENT PATCHED FLOOR IN REAR PREP AND DISH ROOM NO CLEANABLE .NEED TO REPLACE SAID FLOOR TILES AND CEMENT FLOOR,SURFACE MUST BE SMOOTH,CLEANABLE AND NON-ABSORBENT SURFACE. MISSING COVING UNDER THE DISH MACHINE NEED TO BE REPLACED.
-
Walls, Ceilings, Attached Equipment Constructed Per Code: Good Repair, Surfaces Clean And Dust-Less Cleaning MethodsInspector note: BROKEN WALL(HOLE) UNDER THE DISH MACHINE. PEELING PAINT ON WALLS AT SAME AREA AND THROUGHOUT THE KITCHEN.NEED TO REPAIR SAID WALLS.SURFACE MUST BE SMOOTH,CLEANABLE AND NON-ABSORBENT SURFACE DUST BUILD-UP ON CEILING FANS IN DINING ROOMS,NEED TO CLEANAND MAINTAIN
-
Refrigeration And Metal Stem Thermometers Provided And ConspicuousInspector note: NO STEM THERMOMETER PROVIDE ON SITE ,NEED TO PROVIDE TO BE ABLE TO CHECK FOOD TEMPERATURE
-
grimy wiping clothsOfficial wording: Premises Maintained Free Of Litter, Unnecessary Articles, Cleaning Equipment Properly StoredInspector note: EXCESS ITEMS AT EAST NON-FOOD STORAGE AREA,NEED TO ORGANIZE AREA.
What changed since the previous inspection?
Compared with Fail on April 26, 2017: 6 findings recurred. 3 previous findings did not recur.
Browse this restaurant's inspections
More restaurants in Edgewater
About this record
This record comes from Chicago Department of Public Health. Cooked keeps the official result and wording separate from its plain-English explanation so you can verify what the inspector actually published.
Source: Chicago Data Portal.