The Little Corner Snack Shop

May 3, 2017 · Pass
😇clean
  • official resultPass
  • resultPass
  • inspection typeCanvass Re-Inspection
  • failed findings6
  • critical findings0

← Back to the current restaurant page

Failed findings

  • Food And Non-Food Contact Surfaces Properly Designed, Constructed And Maintained
    Inspector note: WASTE LINE FROM COOLER DRIPPING AT THIRD COMPARTMENT SINK.A WASTE LINE MUST BE PROPERLY CONNECTED SUCH THAT IT DRAINS DIRECTLY INTO A FLOOR DRAIN. EXCESS DUCT TAPE ON SHELF BETWEEN THE DISH MACHINE AND METAL SHELF. NEED TO REMOVE DUCT TAPE AND PROVIDE A SPLASH GUARD WITH A SMOOTH, CLEANABLE AND NON-ABSORBENT SURFACE.DUCT TAPE IS PROHIBITED. NO HANDLE PROVIDED AT WHITE REACH-IN FREEZER,DOOR IS HELD WITH A LONG ELASTIC ATTACHED TO STORAGE SHELF.RUBBER GASKET INSIDE THE DOOR IS BROKEN NEED TO REPLACE,AT SAME UNIT. BROKEN AND GRIMED PLASTIC CURTAINS AT INTERIOR OF WALK-IN COOLER NEED TO BE REPLACE,SURFACE MUST BE SMOOTH,CLEANABLE AND NON-ABSORBENT SURFACE
    code 32
  • food prep surfaces dirty
    Official wording: Food And Non-Food Contact Equipment Utensils Clean, Free Of Abrasive Detergents
    Inspector note: EXCESS GREASE INSIDE THE DEEP FRYER,AND EXCESS BURNED FOOD INSIDE THE OVEN. GREASE ON FILTERS AND HOOD,ALSO ON PIPES BEHIND AND UNDER COOKING EQUIPMENT. NEED TO CLEAN AND MAINTAIN. NEED TO REMOVE EXCESS ICE BUILD-UP INSIDE THE UNIT.KEEP IT CLEAN.
    code 33
  • Floors: Constructed Per Code, Cleaned, Good Repair, Coving Installed, Dust-Less Cleaning Methods Used
    Inspector note: MISSING ,BROKEN, UNEVEN FLOOR TILES AND CEMENT PATCHED FLOOR IN REAR PREP AND DISH ROOM NO CLEANABLE .NEED TO REPLACE SAID FLOOR TILES AND CEMENT FLOOR,SURFACE MUST BE SMOOTH,CLEANABLE AND NON-ABSORBENT SURFACE. MISSING COVING UNDER THE DISH MACHINE NEED TO BE REPLACED.
    code 34
  • Walls, Ceilings, Attached Equipment Constructed Per Code: Good Repair, Surfaces Clean And Dust-Less Cleaning Methods
    Inspector note: BROKEN WALL(HOLE) UNDER THE DISH MACHINE. PEELING PAINT ON WALLS AT SAME AREA AND THROUGHOUT THE KITCHEN.NEED TO REPAIR SAID WALLS.SURFACE MUST BE SMOOTH,CLEANABLE AND NON-ABSORBENT SURFACE DUST BUILD-UP ON CEILING FANS IN DINING ROOMS,NEED TO CLEANAND MAINTAIN
    code 35
  • Refrigeration And Metal Stem Thermometers Provided And Conspicuous
    Inspector note: NO STEM THERMOMETER PROVIDE ON SITE ,NEED TO PROVIDE TO BE ABLE TO CHECK FOOD TEMPERATURE
    code 40
  • grimy wiping cloths
    Official wording: Premises Maintained Free Of Litter, Unnecessary Articles, Cleaning Equipment Properly Stored
    Inspector note: EXCESS ITEMS AT EAST NON-FOOD STORAGE AREA,NEED TO ORGANIZE AREA.
    code 41

What changed since the previous inspection?

Compared with Fail on April 26, 2017: 6 findings recurred. 3 previous findings did not recur.