Tiztal Cafe

October 7, 2014 · Pass
😇clean
  • official resultPass
  • resultPass
  • inspection typeCanvass
  • failed findings4
  • critical findings0

← Back to the current restaurant page

Failed findings

  • Floors: Constructed Per Code, Cleaned, Good Repair, Coving Installed, Dust-Less Cleaning Methods Used
    Inspector note: WATER ON FLOOR BETWEEN FLOOR TILES UNDER THE TWO DOOR REACH-IN COOLER,INSTRUCTED TO KEEP FLOOR DRY.
    code 34
  • Walls, Ceilings, Attached Equipment Constructed Per Code: Good Repair, Surfaces Clean And Dust-Less Cleaning Methods
    Inspector note: SCRAPED /PEELING WALL ON STORAGE / PREP AREA BY THE SMALL CHEST FREEZER NEED TO BE REPAIRED,SURFACE MUST BE SMOOTH,CLEANABLE AND NON-ABSORBENT MATERIAL
    code 35
  • thermometers missing
    Official wording: Lighting: Required Minimum Foot-Candles Of Light Provided, Fixtures Shielded
    Inspector note: BROKEN LIGHT COVER IN KITCHEN NEED TO BE REPLACED.LIGHT COVER PLASTIC TUBES ARE INSTALLED AT LIGHTS IN KITCHEN,HOWEVER END CAPS ARE MISSING.INSTRUCTED TO PROVIDED END CAPS AT SAID LIGHTS.
    code 36
  • pests in the house
    Official wording: Ventilation: Rooms And Equipment Vented As Required: Plumbing: Installed And Maintained
    Inspector note: FAUCET IS LEAKING AT THREE COMPARTMENT SINK,INSTRUCTED TO REPAIR.NO BACK FLOW PREVENTER DEVICE PROVIDED AT FAUCET IN BASEMENT AREA.
    code 38

What changed since the previous inspection?

Compared with Pass on February 13, 2014: 3 findings appeared for the first time. 1 finding recurred.

Browse this restaurant's inspections