Wild Goose Bar & Grill

September 30, 2015 · Fail
🪳cooked
  • official resultFail
  • resultFail
  • inspection typeCanvass
  • failed findings7
  • critical findings0

← Back to the current restaurant page

Failed findings

  • surfaces not properly sanitized
    Official wording: Food Protected During Storage, Preparation, Display, Service And Transportation
    Inspector note: OBSERVED ACCUMULATED PINK/BLACK SLIME BUILD UP INSIDE ICE MACHINE DRIPPING INTO ICE, READY TO EAT FOOD. INSTRUCTED MANAGER TO CLEAN AND SANITIZE INTERIOR OF ICE MACHINE AND DISCARD ALL ICE INSIDE ICE MACHINE, ICE CANNOT BE USED FOR CONSUMPTION. SERIOUS VIOLATION 7--38-005(A).
    code 16
  • toxic chemicals mishandled
    Official wording: Previous Minor Violation(S) Corrected 7-42-090
    Inspector note: PREVIOUS MINIOR VIOLATION FROM REPORT #1494096 DATED ON 08/27/14 NOT CORRECTED-#38 NO EXPOSED HANDWASH BOWL BEHIND BAR AREA, MUST PROVIDE EXPOSED HANDWASH BOWL BEHIND BAR WITH RUNNING HOT AND COLD WATER. SERIOUS VIOLATION 7-42-090 NON COMPLIANCE.
    code 29
  • Food And Non-Food Contact Surfaces Properly Designed, Constructed And Maintained
    Inspector note: PREP AREA STAND UP REACH IN COOLER DOOR RUBBER GASKETS RIPPED. INSTRUCTED MANAGER TO REPAIR/REPLACE DAMAGED DOOR RUBBER GASKETS.
    code 32
  • food prep surfaces dirty
    Official wording: Food And Non-Food Contact Equipment Utensils Clean, Free Of Abrasive Detergents
    Inspector note: OBSERVED ACCUMULATED LIQUID BUILD UP ON EXTERIOR OF GREASE TRAP. INSTRUCTED MANAGER TO CLEAN AND MAINTAIN INTERIOR/EXTERIOR OF GREASE TRAP.
    code 33
  • Walls, Ceilings, Attached Equipment Constructed Per Code: Good Repair, Surfaces Clean And Dust-Less Cleaning Methods
    Inspector note: OBSERVED FOOD STAINS/FOOD DEBRIS ON WALLS AT PREP/DISHWASH AREA. INSTRUCTED MANAGER TO CLEAN WALLS AND MAINTAIN.
    code 35
  • thermometers missing
    Official wording: Lighting: Required Minimum Foot-Candles Of Light Provided, Fixtures Shielded
    Inspector note: PREP AREA CEILING LIGHT BULBS MISSING COVER END CAPS. INSTRUCTED MANAGER TO PROVIDE END CAPS FOR PREP AREA CEILING LIGHT BULBS.
    code 36
  • pests in the house
    Official wording: Ventilation: Rooms And Equipment Vented As Required: Plumbing: Installed And Maintained
    Inspector note: NO BACKFLOW PREVENTION DEVICE AT ICE MACHINE WATER LINE. INSTRUCTED MANAGER TO PROVIDE/MAKE VISIBLE BACKFLOW PREVENTION DEVICE AT ICE MACHINE WATER LINE.
    code 38

What changed since the previous inspection?

Compared with Pass on August 27, 2014: 4 findings appeared for the first time. 3 findings recurred. 3 previous findings did not recur.

Browse this restaurant's inspections

About this record

This record comes from Chicago Department of Public Health. Cooked keeps the official result and wording separate from its plain-English explanation so you can verify what the inspector actually published.

Source: Chicago Data Portal.

official city health-inspection data · no account, no sign-up