Failed findings
-
cold food not cold enoughOfficial wording: Dish Machines: Provided With Accurate Thermometers, Chemical Test Kits And Suitable Gauge CockInspector note: FOUND NO CHEMICAL TEST STRIPS FOR THE THREE COMP SINK OR LOW TEMP DISHMACHINE; MUST PROVIDE CHLORINE CHEMICAL TEST STRIPS TO TEST THE STRENGTH OF THE SANITIZER AT THE THREE COMP SINK AND LOW TEMP DISHMACHINE. SERIOUS VIOLATION 7-38-030.
-
Dish Washing Facilities: Properly Designed, Constructed, Maintained, Installed, Located And OperatedInspector note: THE LOW TEMP DISHMACHINE IS NOT REACHING THE REQUIRED TEMPERATURE (120F-140F) DURING THE RINSE CYCLE. AFTER RUNNING THE MACHINE THREE TIMES IT REACHED 110F. ALSO THE CHLORINE CHEMICAL READING WAS BELOW THE REQUIRED 100PPM. INSTRUCTED TO HAVE MACHINE SERVICED SO THAT THE CHEMICAL READING IS 100PPM AND THE RINSE TEMPERATURE IS BETWEEN 120F AND 140F. MACHINE TAGGED HELD FOR INSPECTION AT THIS TIME. INSTRUCTED TO MANUALLY WASH RINSE AND SANITIZE AT THE THREE COMP SINK UNTIL THE DISHMACHINE IS REPAIRED AND HAS BEEN REINSPECTED BY THE CDPH. SERIOUS VIOLATION 7-38-030.
-
food prep surfaces dirtyOfficial wording: Food And Non-Food Contact Equipment Utensils Clean, Free Of Abrasive DetergentsInspector note: MUST CLEAN INTERIOR BOTTOM OF MILK COOLER IN THE FRONT PREP AREA. MUST CLEAN THE EXTERIOR SURFACES OF THE STOVE IN PREP AREA.
-
Floors: Constructed Per Code, Cleaned, Good Repair, Coving Installed, Dust-Less Cleaning Methods UsedInspector note: CLEAN FLOORS UNDER AROUND AND BEHIND KITCHEN EQUIPMENT. ALSO CLEAN AND MAINTAIN THE FLOOR DRAIN UNDER THE THREE COMP SINK.
-
pests in the houseOfficial wording: Ventilation: Rooms And Equipment Vented As Required: Plumbing: Installed And MaintainedInspector note: MUST REMOVE DUST FROM THE VENTILATION FANS ON THE CEILING OF BOTH WASHROOMS.
-
Refrigeration And Metal Stem Thermometers Provided And ConspicuousInspector note: MUST PROVIDE AN INTERNAL THERMOMETER FOR THE MILK COOLER IN THE FRONT PREP AREA.
What changed since the previous inspection?
Compared with Pass on June 15, 2016: 3 findings appeared for the first time. 3 findings recurred. 2 previous findings did not recur.