Peka
September 22, 2026 · Fail
cooked
- official resultFail
- resultFail
- inspection typeEating & Drinking
- failed findings4
- critical findings1
Failed findings
-
Backflow Prevention (P)criticalInspector note: At the two bay prep sink observed a direct connection to the waste water system; have a licensed plumber pull permits at 1010 Mass Ave and install an indirect connection to the wastewater system at the prep sinks.
-
Good Repair and Proper Adjustment-Equipment (C)Inspector note: Observed multiple damaged or missing gaskets for cold holding units in the kitchen; repair or replace the damaged or missing gaskets.
-
System Maintained in Good Repair (C)Inspector note: At the high temperature warewashing machine the rinse gauge and the PSI gauge wash and rinse gauges did not move during any part of the cycles observed; repair or replace the gauges. An irreversible thermometer was used at the machine and registered at least 165F captured.
-
Repairing-Premises Structures Attachments and Fixtures-Methods (C)Inspector note: The floor in front of the walk-in freezer in the basement are heavily damaged; repair or replace the damaged floor
Checks marked passed
-
Manual and Mechanical Warewashing Equipment Chemical Sanitization-Temperature pH Concentration and Hardness (P)criticalInspector note: At the bar chemical warewashing machine tested 0ppm chlorine after multiple run attempts; the person in charge placed a call for service during the inspection and has instructed staff to use the warewashing machine in the kitchen to wash and sanitize until the warewashing machine at the bar is repaired. Chemical sanitizer should be at minimum ppm required by the food code.
-
Clean-up of Vomiting and Diarrheal Events (Pf)Inspector note: No written instructions on how to handle a vomit and diarrhea event could be presented during the inspection; provide.
-
Food Temperature Measuring Devices (Pf)Inspector note: The presented food thermometer was only capable of measuring ambient and hot foods; provide a thin stemmed food thermometer capable of measuring cold and hot foods.
-
Maintaining Refuse Areas and Enclosures (C)Inspector note: There is excessive refuse and items scattered around the exterior refuse area; remove the excessive items to prevent pest harborage.
-
Toilet Room Receptacle Covered (C)Inspector note: Provide a covered waste receptacle in the employee restroom for sanitary products.
-
Handwashing Signage (C)Inspector note: The first floor woman's room and the employee restroom in the basement lack handwashing signage; provide.
What changed since the previous inspection?
Compared with Fail on September 15, 2026: 4 findings recurred. 6 previous findings did not recur.