Ba Le Sandwiches Et Cafe 2

September 2, 2011 · Fail
🪳cooked
  • official resultFail
  • resultFail
  • inspection typeLicense
  • failed findings7
  • critical findings1

← Back to the current restaurant page

Failed findings

  • certified manager paperwork missingcritical
    Official wording: Facilities To Maintain Proper Temperature
    Inspector note: All food establishments that display, prepare, or store potentially hazardous food shall have adequate refrigerated food storage facilities. All food establishments that prepare, sell, or store hot food shall have adequate hot food storage facilities. NEWLY INSTALLED BEVERAGE REFRIGERATION UNITS ON SITE. INSTRUCTED TO MAINTAIN COLD TEMPERATURE AT 40F AND BELOW AT ALL TIMES. HOT HOLDING UNIT AT 114.5F. INSTRUCTED TO KEEP HOT TEMPERATURE AT 140F AND ABOVE. CRITICAL 7-38-005(A) NO CITATION ISSUED.
    code 2Priority
  • Food And Non-Food Contact Surfaces Properly Designed, Constructed And Maintained
    Inspector note: All food and non-food contact equipment and utensils shall be smooth, easily cleanable, and durable, and shall be in good repair. PROVIDE RACKS/SHELVES FOR DRY STORAGE AREA IN BASEMENT AND INSIDE WALK-IN COOLER AND WALK-IN FREEZER. OBSERVED FELT MATERIAL ON DOUGH ROLLER NOT SMOOTH AND EASILY CLEANABLE, INSTRUCTED TO PROVIDE MATERIAL PER CODE.
    code 32
  • food prep surfaces dirty
    Official wording: Food And Non-Food Contact Equipment Utensils Clean, Free Of Abrasive Detergents
    Inspector note: CLEAN INTERIOR OF MICROWAVE, DOUGH DIVIDER, INSIDE HOT HOLDING UNIT TO REMOVE FOOD DEBRIS.
    code 33
  • Floors: Constructed Per Code, Cleaned, Good Repair, Coving Installed, Dust-Less Cleaning Methods Used
    Inspector note: The floors shall be constructed per code, be smooth and easily cleaned, and be kept clean and in good repair. CLEAN FLOORS ALONG WALL BASE IN BASEMENT, REMOVE EXCESS FOAM FROM FLOOR BETWEEN WALK-IN UNITS. KEEP FLOORS DRY AROUND
    code 34
  • Walls, Ceilings, Attached Equipment Constructed Per Code: Good Repair, Surfaces Clean And Dust-Less Cleaning Methods
    Inspector note: The walls and ceilings shall be in good repair and easily cleaned. INSTRUCTED TO FINISH PAINTING, SEALING DRY WALL IN BASEMENT STORAGE AREA, PROVIDE CEILING PANELS FOR MISSING SECTIONS AT REAR PREP AREA, AND BASEMENT STORAGE AREA TO MAKE SMOOTH AND EASILY CLEANABLE. PAINT RAW WOOD BEAMS IN BASEMENT. SEAL EXPOSED INSULATION AT WALL IN BASEMENT. SEAL LARGE OPENINGS AT UPPER WALLS BY HOT WATER TANK AND BASEMENT STAIRS.
    code 35
  • pests in the house
    Official wording: Ventilation: Rooms And Equipment Vented As Required: Plumbing: Installed And Maintained
    Inspector note: REPAIR LEAKS AT FACUET CONNECTION AT THREE COMPARTMENT SINK AND HOSE CONNECTED TO UTILTIY SINK AT ECOLAB DISPENSER. PROVIDE WORKING VENTILATION AT FRONT PREP AREA. REMOVE PLUMBERS PUTTY FROM AROUND DRAINS AT EXPOSED HAND WASH SINK, ONE COMPARTMENT SINK, AND THREE COMPARTMENT SINK.
    code 38
  • Refrigeration And Metal Stem Thermometers Provided And Conspicuous
    Inspector note: All food establishments that display, prepare, or store potentially hazardous foods shall have calibrated metal stem thermometers, provided and conspicuous, for refrigerated and hot food units.
    code 40