Banquets - Main Kitchen
October 3, 2011 · Fail
🪳cooked
- official resultFail
- resultFail
- inspection typeComplaint
- failed findings5
- critical findings0
Failed findings
-
Dish Washing Facilities: Properly Designed, Constructed, Maintained, Installed, Located And OperatedInspector note: (7-38-030)- (INADEQUATE PLUMBING) NOTED WATER LEAKING PROFUSELY ON TO THE FLOOR UNDER THE SANITIZING SECTION OF THE 3-COMP. SINK AT POTWASHING AREA-MUST FIX. All dishwashing machines must be of a type that complies with all requirements of the plumbing section of the Municipal Code of Chicago and Rules and Regulation of the Board of Health.
-
Food And Non-Food Contact Surfaces Properly Designed, Constructed And MaintainedInspector note: ICE BUILD-UP ON CONDENSER OF SMALL COOLER AT SOUTH WALL OF CAFETERIA PREP LINE-MUST FIX. All food and non-food contact equipment and utensils shall be smooth, easily cleanable, and durable, and shall be in good repair.
-
Floors: Constructed Per Code, Cleaned, Good Repair, Coving Installed, Dust-Less Cleaning Methods UsedInspector note: FLOORS ALONG WALLBASES UNDER HEAVY EQUIPMENT IN PREP AREAS & UNDER SINKS IN DISHROOMS MUST BE FREE OF DEBRIS/DIRT. ALL FLOOR DRAINS & COVERS THRU-OUT PREMISES NEED CLEANING ALSO. The floors shall be constructed per code, be smooth and easily cleaned, and be kept clean and in good repair.
-
Walls, Ceilings, Attached Equipment Constructed Per Code: Good Repair, Surfaces Clean And Dust-Less Cleaning MethodsInspector note: OPENING ON THE WALL UNDER HANDSINK IN CAFETERIA & UNDER POTWASK SINK IN MAIN KITCHEN; PEELING PAINT ON CEILING AT SILVERWARE DISHROOM (5th FL)& MILDEW ON CEILING ABOVE THIS SAME SINK-MUST BE ADDRESSED. WALLS AROUND GARBAGE BINS MUST BE FREE OF FOOD STAINS. The walls and ceilings shall be in good repair and easily cleaned.
-
pests in the houseOfficial wording: Ventilation: Rooms And Equipment Vented As Required: Plumbing: Installed And MaintainedInspector note: MOST WASHERS ON SINK FAUCETS THRU-OUT FACILITY ARE LEAKING-MUST FIX. Ventilation: All plumbing fixtures, such as toilets, sinks, washbasins, etc., must be adequately trapped, vented, and re-vented and properly connected to the sewer in accordance with the plumbing chapter of the Municipal Code of Chicago and the Rules and Regulations of the Board of Health.
What changed since the previous inspection?
Compared with Pass on February 25, 2011: 1 finding appeared for the first time. 4 findings recurred. 2 previous findings did not recur.