Cafe Iberico
January 12, 2015 · Fail
🪳cooked
- official resultFail
- resultFail
- inspection typeComplaint
- failed findings5
- critical findings0
Failed findings
-
toxic chemicals mishandledOfficial wording: Previous Minor Violation(S) Corrected 7-42-090Inspector note: PREVIOUS MINOR VIOLATIONS NOT CORRECTED FROM REPORT #1490436 DATED 7/9/14.#32-NOTED RUSTY AND DIRTY SHELVES INSIDE WALK IN COOLER SHELVINGS RACK WITH SAUCEPANS BY THE STOVE.IST FLOOR AND SHELVES INSIDE THE SERVICE COOLER AT THE DESSERT PREP AREA. INSTRUCTED TO CLEAN,REPAINT WITH NON TOXIC FOOD GRADE OR REPLACE . NOTED THICK GREASE AND DIRT ON THE ELECTRICAL UNITS OF DEEP FRYER AT THE PREP AREAS. INSTRUCTED TO CLEAN AND MAINTAIN. #33- INSTRUCTED TO CLEAN INSIDE UPPER COMPARTMENT OF ICE MACHJINE WITH SLIGHT YELLOWISH DISCOLORATION. SANITIZE AND MAINTAIN. CITATION ISSUED SERIOUS 7-42-090.
-
Food And Non-Food Contact Surfaces Properly Designed, Constructed And MaintainedInspector note: MUST INSTALL A SPLASH GUARD BETWEEN THE DRAIN BOARD FOR CLEAN GLASSES AND THE ICE BIN ON THE 2ND FLOOR BAR,AND BETWEEN THE EXPOSED HAND SINK AND THE DRAIN BOARD OF THE 3 COMPARTMENT SINK ON THE 2ND FLOOR KITCHEN. MUST PROVIDE LIDS FOR ALL ICE BINS WITH CONSUMMABLE ICE BEHIND ALL BARS. ONE OUT OF 5 CHEST FREEZERS WITH BROKEN INTERIOR PANEL OF THE DOOR. MUST REPAIR/REPLACE. MUST RE CAULK ALONG THE SPLASH GUARD OF THE 3 COMPARTMENT SINK AND EXPOSED HAND SINK IN THE NORTH KITCHEN,(CAULK WORN OUT WITH BLACK MOLDY LIKE SUBSTANCE).
-
Walls, Ceilings, Attached Equipment Constructed Per Code: Good Repair, Surfaces Clean And Dust-Less Cleaning MethodsInspector note: VENT COVER IN BOTH MEN'S AND WOMEN'S WASHROOM 1ST FLOOR WITH DUST ACCUMULATED. MUST CLEAN AND MAINTAIN. RUSTED WALLS,DOOR AND CEILING OF THE WALK IN COOLER. MUST REMOVE RUST AND MAINTAIN. CEILING AND VENT COVER ON THE SIDE OF THE HOOD IN THE NORTH KITCHEN WITH HEAVY GREASE ACCUMULATED, MUST CLEAN IN DETAIL AND MAINTAIN.
-
thermometers missingOfficial wording: Lighting: Required Minimum Foot-Candles Of Light Provided, Fixtures ShieldedInspector note: BURNED OUT LIGHT BULBS x2 ON THE HOOD IN THE 2ND FLOOR KITCHEN. MUST REPLACE.
-
pests in the houseOfficial wording: Ventilation: Rooms And Equipment Vented As Required: Plumbing: Installed And MaintainedInspector note: 3 COMPARTMENT SINKS IN BOTH 2 KITCHEN HAS NO DRAIN STOPPERS. MUST PROVIDE DRAIN STOPPERS.
What changed since the previous inspection?
Compared with Pass w/ Conditions on July 9, 2014: 2 findings appeared for the first time. 3 findings recurred. 8 previous findings did not recur.
Browse this restaurant's inspections
More restaurants in Near North Side
About this record
This record comes from Chicago Department of Public Health. Cooked keeps the official result and wording separate from its plain-English explanation so you can verify what the inspector actually published.
Source: Chicago Data Portal.