Kabuki Restaurant

July 26, 2011 · Fail
🪳cooked
  • official resultFail
  • resultFail
  • inspection typeLicense-Task Force
  • failed findings10
  • critical findings4

← Back to the current restaurant page

Failed findings

  • certified manager paperwork missingcritical
    Official wording: Facilities To Maintain Proper Temperature
    Inspector note: All food establishments that prepare, sell, or store hot food shall have adequate hot food storage facilities. SMALL DISPLAY COOLER IN SUSHI AREA NOT MAINTAINING ADEQUATED TEMPERATURE PRESENT AIR TEMP OF 50F.INSTRUCTED MUST MAINYTAIN 40F AND BELOW.TAGGED UNIT"HELD FOR INSPECTION".FAX A LETTER WHEN UNIT IS REPAIRED.(FAX #312-746-4240).CRITICAL VIOLATION -NO CITATION ISSUED NOT OPERATING. MANAGER WAS ABLE TO TURN DOWN TEMPERATURE CONTROL WHICH PRESENTLY AIR TEMP IS 37.9F
    code 2Priority
  • sick-employee policy not followedcritical
    Official wording: Potentially Hazardous Food Meets Temperature Requirement During Storage, Preparation Display And Service
    Inspector note: All cold food shall be stored at a temperature of 40F or less. FOUND FOOD STORED INSIDE THE ABOVE COOLER AT IMPROPER TEMPERATURE:CRAB MEAT AT TEMP OF 46.4F AND SEA WEED SALAD AT TEMP OF 46.5F.FOOD DISCARDED AND DENATURED.CRITICAL VIOLATION-NO CITATION ISSUED.
    code 3Priority
  • handwashing sink issuescritical
    Official wording: Sanitizing Rinse For Equipment And Utensils: Clean, Proper Temperature, Concentration, Exposure Time
    Inspector note: Equipment and utensils should get proper exposure to the sanitizing solution during the rinse cycle. Bactericidal treatment shall consist of exposure of all dish and utensil surfaces to a rinse of clean water at a temperature of not less than 180F. LOW TEMP DISH MACHINE NOT ABLE TO DISPENSE SANITIZE SOLUTION(0PPM).TAGGED UNIT "HELD FOR INSPECTION" DO NOT USE.INSTRUCTED TO REPAIR MUST PROVIDE 100PPM.CRITICAL VIOLATION -NO CITATION ISSUED.
    code 8Priority
  • water/temperature at the sink offcritical
    Official wording: Water Source: Safe, Hot & Cold Under City Pressure
    Inspector note: All food establishments shall be provided with an adequate supply of hot and cold water under pressure properly connected to the city water supply. NO HOT WATER PROVIDED THROUGHOUT THE PREMISES.INSTRUCTED TO PROVIDE IT.MUST REMAIN CLOSED UNTIL HOT WATER IS PROVIDED ON PREMISES.CRITICAL VIOLATION-NO CITATION ISSUED.
    code 9Priority
  • Outside Garbage Waste Grease And Storage Area; Clean, Rodent Proof, All Containers Covered
    Inspector note: The area outside of the establishment used for the storage of garbage shall be clean at all times and shall not constitute a nuisance. OUTSIDE WASTE OIL CONTAINER NOT CLEANED.INSTRUCTED TO CLEAN LID(DEBRIS).SERIOUS VIOLATION-NO CITATION ISSUED.
    code 19
  • Food And Non-Food Contact Surfaces Properly Designed, Constructed And Maintained
    Inspector note: All food and non-food contact equipment and utensils shall be smooth, easily cleanable, and durable, and shall be in good repair. NEED TO PAINT WITH NON-TOXIC PAINT RUSTY SHELVES INSIDE THE WALK-IN COOLER, OR REPLACE THEM.PROVIDE A DRAIN LINE TO A FLOOR DRAIN AT SUSHI REFRIGERATOR.ALL RAW WOOD SHELVES MUST BE PAINTED, SURFACE MUST BE SMOOTH, CLEANABLE AND NON-ABSORBENT MATERIAL.MUST CHANGE SHELVES BEHIND THE SMALL BAR.
    code 32
  • food prep surfaces dirty
    Official wording: Food And Non-Food Contact Equipment Utensils Clean, Free Of Abrasive Detergents
    Inspector note: All food and non-food contact surfaces of equipment and all food storage utensils shall be thoroughly cleaned and sanitized daily. CLEAN SIDE OF COOKING EQUIPMENT IN PREP AREA.DETAIL CLEAN INSIDE THE MOP SINK(TOO MUCH FLOOR DEBRI).
    code 33
  • Floors: Constructed Per Code, Cleaned, Good Repair, Coving Installed, Dust-Less Cleaning Methods Used
    Inspector note: The floors shall be constructed per code, be smooth and easily cleaned, and be kept clean and in good repair. REPLACE MISSING AND BROKEN FLOOR TILES THROUGHOUT THE PREMISES,INCLUDED UNDER THE DISH MACHINE AND AROUND FLOOR DRAIN IN PREP AREA BASEMENT.RESEAL TOILET FLOOR HOLE IN BASEMENT AREA(STRONG FOUL ODOR)SWEEP FLOOR THROUGHOUT THE BASEMENT STORAGE AREAS,THROUGHOUT.
    code 34
  • Walls, Ceilings, Attached Equipment Constructed Per Code: Good Repair, Surfaces Clean And Dust-Less Cleaning Methods
    Inspector note: The walls and ceilings shall be in good repair and easily cleaned. CLEAN AND PAINT WALL UNDER THE 3 COMPARTMENT SINKS(BOTH PREP AREA).SEDAL ALL HOLE THROUGHOUT THE PREMISES,INCLUDED AROUND THE PIPE, INSIDE THE CABINET IN BOTH WASHROOMS.
    code 35
  • pests in the house
    Official wording: Ventilation: Rooms And Equipment Vented As Required: Plumbing: Installed And Maintained
    Inspector note: Ventilation: All plumbing fixtures, such as toilets, sinks, washbasins, etc., must be adequately trapped, vented, and re-vented and properly connected to the sewer in accordance with the plumbing chapter of the Municipal Code of Chicago and the Rules and Regulations of the Board of Health. A NEW EXPOSED HAND SINK IS NEEDED AT SUSHI BAR(IN POOR REPAIR).PROPER INSTALLED WATER PIPE IS NEEDED. STOPPER IS NEEDED AT BOTH 3 COMPARTMENT SINK. PROVIDE A BACK FLOW PREVENTER FOR THE HOSE ATTACHED AT FAUCET NEXT TO EXPOSED HAND SINK IN BASEMENT AREA.
    code 38