Failed findings

  • sick-employee policy not followedcritical
    Official wording: Potentially Hazardous Food Meets Temperature Requirement During Storage, Preparation Display And Service
    Inspector note: THE FOLLOWING POTENTIALLY HAZARDOUS FOODS AT IMPROPER TEMPERATURES RANGING FROM 57.2-63.9F IN WALK-IN COOLER: LARGE COVERED DEEP CONTAINERS OF COOKED PORK, CHICKEN, BEEF, CARNE ASADA AND SOUP. MGR STATES COOKED YESTERDAY. INSTD MGR ON PROPER COOLING TECHNIQUES. ALL PRODUCT VOLUNTARILY DISCARDED AND DENATURE AT THIS TIME. APPROX 40LBS $250 VALUE. CITATION ISSUED 7-38-005A CRITICAL
    code 3Priority
  • Food And Non-Food Contact Surfaces Properly Designed, Constructed And Maintained
    Inspector note: CUTTING BOARDS STAINED WITH DEEP DARK GROOVES. INSTD TO REPAIR/REPLACE SAME. RAW WOOD STORAGE SHELVES IN TAQUERIA. INSTD TO PAINT/SEAL SAME.
    code 32
  • food prep surfaces dirty
    Official wording: Food And Non-Food Contact Equipment Utensils Clean, Free Of Abrasive Detergents
    Inspector note: INTERIOR OF HOT HOLDING UNIT, SINKS, SHELVES, SIDES OF COOKING EQUIPMENT, CUTTING BOARD, AND MULTI-USE UTENSILS IN TAQUERIA NOT CLEAN, DEBRIS INSTD TO CLEAN SAME AND MAINTAIN.
    code 33
  • thermometers missing
    Official wording: Lighting: Required Minimum Foot-Candles Of Light Provided, Fixtures Shielded
    Inspector note: LIGHT OUT IN MILK WALK-IN COOLER. REPLACE SAME.
    code 36
  • pests in the house
    Official wording: Ventilation: Rooms And Equipment Vented As Required: Plumbing: Installed And Maintained
    Inspector note: STOVES (4-BURNER AND 1-BURNER) IN REAR WITHOUT PROPER VENTILATION. INSTD TO PROVIDE PROPER COMMERCIAL VENTILATION THAT EXTENTDS ABOVE ROOF LINE OR REMOVE STOVES FROM PREMISES.
    code 38
  • Refrigeration And Metal Stem Thermometers Provided And Conspicuous
    Inspector note: METAL STEM THERMOMETER AND REFRIGERATION THERMOMETERS FOR DELI COOLER MISSING.
    code 40

What changed since the previous inspection?

Compared with Pass on November 14, 2013: 3 findings appeared for the first time. 3 findings recurred. 2 previous findings did not recur.

Browse this restaurant's inspections

About this record

This record comes from Chicago Department of Public Health. Cooked keeps the official result and wording separate from its plain-English explanation so you can verify what the inspector actually published.

Source: Chicago Data Portal.