✓!

Snarf's

April 22, 2015 · Pass w/ Conditions
😬mid
  • official resultPass w/ Conditions
  • resultPass w/ Conditions
  • inspection typeCanvass
  • failed findings9
  • critical findings0

← Back to the current restaurant page

Failed findings

  • hot/cold holding temps off
    Official wording: * Certified Food Manager On Site When Potentially Hazardous Foods Are Prepared And Served
    Inspector note: NO CERTIFIED FOOD MANAGER WHILE PREPARING AND SERVING POTENTIALLY HAZARDOUS FOODS ESTABLISHMENT OPEN FOR BUSINESS AT 7:00AM. CITATION ISSUED SERIOUS 7-38-012. CERTIFIED MANAGER MARCUS WILLIAMS ARRIVED AT 9:25AM DURING INSPECTION
    code 21
  • Clean Multi-Use Utensils And Single Service Articles Properly Stored: No Reuse Of Single Service Articles
    Inspector note: ALL SINGLE SERVICE UTENSILS, POTS, PANS, FOOD CONTAINERS MUST BE STORED UPSIDE DOWN/INVERTED.
    code 31
  • Food And Non-Food Contact Surfaces Properly Designed, Constructed And Maintained
    Inspector note: MUST PROVIDE LID FOR THE ICE BIN IN THE COFFEE STATION.
    code 32
  • food prep surfaces dirty
    Official wording: Food And Non-Food Contact Equipment Utensils Clean, Free Of Abrasive Detergents
    Inspector note: ONE OUT OF TWO FAN GUARD OF THE 3 DOOR REACH IN COOLER IN THE FRONT AREA BY THE COFFEE STATION WITH DUST ACCUMULATED. MUST CLEAN AND MAINTAIN.
    code 33
  • Walls, Ceilings, Attached Equipment Constructed Per Code: Good Repair, Surfaces Clean And Dust-Less Cleaning Methods
    Inspector note: BEAM SUPPORT IN THE PREP FRONT AND REAR AREA MUST BE SMOOTH EASILY CLEANABLE. MUST SEAL ALL THE GAP AROUND THE CONDUIT AND PIPES THRU-OUT REAR PREP AREA/KITCHEN .
    code 35
  • thermometers missing
    Official wording: Lighting: Required Minimum Foot-Candles Of Light Provided, Fixtures Shielded
    Inspector note: ONE BURNED OUT LIGHT BULB ON THE HOOD IN THE COOK LINE FRONT AREA. MUST REPLACE.
    code 36
  • food improperly labeled
    Official wording: Toilet Room Doors Self Closing: Dressing Rooms With Lockers Provided: Complete Separation From Living/Sleeping Quarters
    Inspector note: MUST RE ADJUST BOTH SELF CLOSER DEVICE ON BOTH WASHROOMS. DOOR NOT CLOSING ALL THE WAY.
    code 37
  • pests in the house
    Official wording: Ventilation: Rooms And Equipment Vented As Required: Plumbing: Installed And Maintained
    Inspector note: HOT WATER HANDLE OF THE 3 COMPARTMENT SINK IN THE COFFEE STATION NOT IN GOOD REPAIR. MUST REPAIR AND MAINTAIN. MUST INSTALL A FAUCET WITH HOT AND COLD RUNNING WATER ON TOP OF THE TAYLOR MACHINE. LEAK ON THE FAUCET CONNECTOR OF THE 2 FAUCET OF THE 3 COMPARTMENT SINK. MUST REPAIR AND MAINTAIN.
    code 38
  • Food Handler Requirements Met
    Inspector note: NO FOOD HANDLER'S CERTIFICATE ON SITE. MUST PROVIDE NEXT ROUTINE INSPECTION.
    code 45

What changed since the previous inspection?

Compared with Pass w/ Conditions on September 3, 2014: 7 findings appeared for the first time. 2 findings recurred. 2 previous findings did not recur.

Browse this restaurant's inspections

About this record

This record comes from Chicago Department of Public Health. Cooked keeps the official result and wording separate from its plain-English explanation so you can verify what the inspector actually published.

Source: Chicago Data Portal.

official city health-inspection data · no account, no sign-up