Subway

November 10, 2016 · Fail
🪳cooked
  • official resultFail
  • resultFail
  • inspection typeCanvass
  • failed findings6
  • critical findings0

← Back to the current restaurant page

Failed findings

  • toxic items stored near food
    Official wording: No Evidence Of Rodent Or Insect Outer Openings Protected/Rodent Proofed, A Written Log Shall Be Maintained Available To The Inspectors
    Inspector note: Found/observed front entrance/exit revolving door not rodent proofed, door had gaps on bottom of door ranging from 1/4 inch, to 1/2 inch or greater, citation issued 7-38-020, serious violation.
    code 18
  • Food And Non-Food Contact Surfaces Properly Designed, Constructed And Maintained
    Inspector note: Prep table lower shelving that had peeling paint in rear prep area, shall be repaired/sealed. Caulk around exposed hand sink in front prep area in state of disrepair, shall be repaired/replaced. Caulk around bathrooms(men's, woman's) in state of disrepair, (sinks loose), shall be repaired/replaced.
    code 32
  • food prep surfaces dirty
    Official wording: Food And Non-Food Contact Equipment Utensils Clean, Free Of Abrasive Detergents
    Inspector note: Prep table lower shelving not clean, need detailed cleaning(crevices). Reach in cooler shelving/racks that had peeling paint/rust in front prep area, shall be repaired/replaced. Non food contact surfaces of pop dispensing unit not clean, need detailed cleaning(crevices).
    code 33
  • Floors: Constructed Per Code, Cleaned, Good Repair, Coving Installed, Dust-Less Cleaning Methods Used
    Inspector note: Floors under pop dispensing unit not clean, had excess grease build up, need detailed cleaning(corners).
    code 34
  • thermometers missing
    Official wording: Lighting: Required Minimum Foot-Candles Of Light Provided, Fixtures Shielded
    Inspector note: Missing light shields in rear dry storage room area closet, shall be provided.
    code 36
  • pests in the house
    Official wording: Ventilation: Rooms And Equipment Vented As Required: Plumbing: Installed And Maintained
    Inspector note: Exhaust fans in men's bathroom, and women's, in state of disrepair, not working, shall be repaired/replaced.
    code 38

What changed since the previous inspection?

Compared with Pass on April 26, 2016: 3 findings appeared for the first time. 3 findings recurred. 1 previous finding did not recur.