Sushi Loop

July 8, 2025 · Fail
🪳cooked
  • official resultFail
  • resultFail
  • inspection typeCanvass
  • failed findings8
  • critical findings2

← Back to the current restaurant page

Failed findings

  • handwashing sink blocked or barecritical
    Official wording: Adequate Handwashing Sinks Properly Supplied And Accessible
    Inspector note: OBSERVED HANDWASHING SINK AT THE 1ST FLOOR WOMEN'S WASHROOM REACHING MAXIMUM WATER TEMPERATURE OF 80.0F AT TIME OF LICENSE INSPECTION. INSTRUCTED TO REPAIR OR REPLACE 1ST FLOOR WOMEN'S RESTROOM HANDWASHING SINK TO PROVIDE WATER OF AT LEAST 100.0F AND MAINTAIN AT ALL TIMES. PRIORITY VIOLATION. 7-38-030(C). • OBSERVED HAND SOAP NOT PROVIDED AT THE PRIVATE BAR AREA HANDWASHING SINK. INSTRUCTED TO PROVIDE HAND SOAP AT ALL HANDWASHING SINKS AND MAINTAIN AVAILABLE FOR USE IN HANDWASHING AT ALL TIMES. PRIORITY FOUNDATION VIOLATION. 7-38-030(C). • OBSERVED DISPOSABLE PAPER TOWELS NOT PROVIDED AT THE MAIN KITCHEN 3-COMPARTMENT SINK AREA HANDWASHING SINK. INSTRUCTED TO PROVIDE DISPOSABLE PAPER TOWELS AT ALL HANDWASHING SINKS AND MAINTAIN AVAILABLE FOR USE IN HANDWASHING AT ALL TIMES. PRIORITY FOUNDATION VIOLATION. 7-38-030(C).
    code 10Priority
  • staff working while sickcritical
    Official wording: Procedures For Responding To Vomiting And Diarrheal Events
    Inspector note: OBSERVED NO KIT PROVIDED ON-SITE FOR CLEAN-UP OF VOMITING AND DIARRHEAL EVENTS. INSTRUCTED TO MAINTAIN AT LEAST ONE KIT FOR THE CLEAN-UP OF VOMITING AND DIARRHEAL EVENTS ON-SITE AND AVAILABLE FOR USE AT ALL TIMES. PRIORITY FOUNDATION VIOLATION.
    code 5Priority
  • food prep surfaces dirty
    Official wording: Proper Cooling Methods Used; Adequate Equipment For Temperature Control
    Inspector note: OBSERVED 2-DOOR REACH-IN DRAWER COOLER AT THE REAR KITCHEN PREP AREA TO BE AT IMPROPER INTERNAL TEMPERATURE FOR COLD-HOLDING TCS FOOD, AMBIENT AIR TEMPERATURE OF 48.6F AT TIME OF LICENSE INSPECTION. INSTRUCTED TO REPAIR OR REPLACE REAR KITCHEN PREP AREA 2-DOOR REACH-IN DRAWER COOLER TO MAINTAIN INTERNAL AMBIENT AIR TEMPERATURE TO STORE TCS FOOD AT 41.0F OR BELOW. PRIORITY VIOLATION. 7-38-005.
    code 33
  • thermometers missing
    Official wording: Thermometers Provided & Accurate
    Inspector note: OBSERVED SEVERAL COOLERS THROUGHOUT THE MAIN KITCHEN AREA TO BE MISSING INTERNAL AMBIENT AIR THERMOMETERS. INSTRUCTED TO PROVIDE AT LEAST ONE INTERNAL AMBIENT AIR THERMOMETER IN A CONSPICUOUS AND EASILY-VIEWABLE LOCATION IN ALL EQUIPMENT USED TO COLD-HOLD TCS FOOD ITEMS AND MAINTAIN AT ALL TIMES. • OBSERVED FOOD TEMPERATURE MEASURING PROBE THERMOMETER NOT ACCURATELY CALIBRATED AT TIME OF LICENSE INSPECTION, DISPLAYING TEMPERATURE OF -22.0F AT ROOM TEMPERATURE ENVIRONMENT. INSTRUCTED TO CALIBRATE FOOD TEMPERATURE MEASURING PROBE THERMOMETER WITHIN ±2.0F THE INTENDED RANGE OF USE AND MAINTAIN AT ALL TIMES. PRIORITY FOUNDATION VIOLATION. 7-38-005.
    code 36
  • pests in the house
    Official wording: Insects, Rodents, & Animals Not Present
    Inspector note: OBSERVED NO PEST CONTROL LOG BOOK PROVIDED ON-SITE AT TIME OF LICENSE INSPECTION. INSTRUCTED TO PROVIDE UP-TO-DATE PEST CONTROL LOG BOOK WITH ALL DOCUMENTATION REQUIRED BY THE LAW AND MAINTAIN AVAILABLE FOR INSPECTOR REVIEW ON-SITE AT ALL TIMES. PRIORITY FOUNDATION VIOLATION. 7-38-020(C).
    code 38
  • Warewashing Facilities: Installed, Maintained & Used; Test Strips
    Inspector note: OBSERVED NO QUATERNARY AMMONIUM COMPOUND CHEMICAL SANITIZER TEST KIT PROVIDED ON-SITE AT TIME OF LICENSE INSPECTION. INSTRUCTED TO PROVIDE CHEMICAL SANITIZER TEST KIT FOR ALL CHEMICAL SANITIZERS UTILIZED BY THE FACILITY AND MAINTAIN ON-SITE AT ALL TIMES. PRIORITY FOUNDATION VIOLATION. 7-38-005.
    code 48
  • plumbing acting up
    Official wording: Non-Food/Food Contact Surfaces Clean
    Inspector note: OBSERVED NONFOOD-CONTACT SURFACES (INTERIOR CAVITY) OF KITCHEN AREA REACH-IN DRAWER COOLERS TO BE SOILED WITH DRIED FOOD DEBRIS AND OTHER SOILS. INSTRUCTED TO CLEAN NONFOOD-CONTACT SURFACES OF COLD-HOLDING EQUIPMENT AT ADEQUATE FREQUENCY TO PREVENT BUILD UP OF SOILS AND MAINTAIN.
    code 49
  • floors, walls, or ceilings grimy
    Official wording: Physical Facilities Installed, Maintained & Clean
    Inspector note: OBSERVED FLOOR BENEATH EQUIPMENT IN THE REAR KITCHEN WAREWASHING AREA TO BE HEAVILY SOILED WITH DRIED FOOD DEBRIS AND OTHER SOILS. INSTRUCTED TO CLEAN FLOORS AND OTHER PHYSICAL FACILITIES AT ADEQUATE FREQUENCY TO PREVENT THE BUILD UP OF SOILS AND MAINTAIN.
    code 55