Failed findings

  • Manual Warewashing Equipment Heaters and Baskets (Pf)
    Inspector note: Final rinse of the high temperature dish machine only reading 121F. Discontinue and ensure the final rinse temperature meets the minimum requirement of 180F. 3 Bay sink is to be used if dish machine is not working properly. At the time of the re-inspection the Hobart dish machine was being changed over to a low temperature chemical dish machine.
    code 590.004/4-204.116-PF** · serious findingstatus: Fail