Cooked?

Slade's Bar & Grill

August 14, 2024 · Fail
🪳cooked
  • official resultFail
  • resultFail
  • inspection typeEating & Drinking
  • failed findings7
  • critical findings2

← Back to the current restaurant page

Failed findings

  • (A)(2) and (B) Time/Temperature Control for Safety Food Hot and Cold Holding (P)critical
    Inspector note: Observed cooked rice stored in upright refrigerated unit @ 50F. Discussed with PIC to maintain cold holding @ 41F or below while stored in refrigerated unit. PIC stored in walk in cooler
    code 590.003/3-501.16-P*** · critical food-safety factorstatus: Fail
  • Backflow Prevention Device When Required (P)critical
    Inspector note: Observed no air gap underneath prep sink. Contact licensed plumber to provide to ensure indirect waste.
    code 590.005/5-203.14-P*** · critical food-safety factorstatus: Fail
  • (A) Equipment Food-Contact Surfaces Nonfood-Contact Surfaces and Utensils (Pf)
    Inspector note: Observed ice machine soiled with mold-like substance inside. Clean to remove mold-like substance Observed interior of dry storage bin underneath prep table in kitchen soiled. Clean to remove all food debris
    code 590.004/4-601.11-PF** · serious findingstatus: Fail
  • Food Storage Containers Identified with Common Name of Food (C)
    Inspector note: Observed multiple squeeze bottles without identification of food product. Provide a label with the common name of food item stored inside.
    code 590.003/3-302.12-C* · lower-severity findingstatus: Fail
  • Miscellaneous Sources of Contamination (C)
    Inspector note: Observed soda gun tube stored on clean ice at bar. Re-position holder to prevent tubing from possible contamination of clean ice.
    code 590.003/3-307.11-C* · lower-severity findingstatus: Fail
  • System Maintained in Good Repair (C)
    Inspector note: Observed leak underneath 3 bay compartment sink. Contact licensed plumber for repairs and provide a detailed reports
    code 590.005/5-205.15-C* · lower-severity findingstatus: Fail
  • Cleaning Ventilation Systems Nuisance and Discharge Prohibition (C)
    Inspector note: Observed hood sticker expired July 2024. PIC contacted hood cleaning company while on site - scheduled for Saturday August 17
    code 590.006/6-501.14-C* · lower-severity findingstatus: Fail

What changed since the previous inspection?

Compared with Pass on April 12, 2024: 7 findings appeared for the first time.

Browse this restaurant's inspections

About this record

This record comes from Boston Inspectional Services, Health Division. Cooked keeps the official result and wording separate from its plain-English explanation so you can verify what the inspector actually published.

Source: Analyze Boston.

official city health-inspection data · no account, no sign-up