May 31, 2017 · Pass
😇clean
  • official resultPass
  • resultPass
  • inspection typeLicense Re-Inspection
  • failed findings6
  • critical findings0

← Back to the current restaurant page

Failed findings

  • Food And Non-Food Contact Surfaces Properly Designed, Constructed And Maintained
    Inspector note: UNFINISHED, NON-SEALED BRICK AND CONCRETE SURROUND OF BRICK OVEN. MUST SEAL TO BE EASILY CLEANABLE AND NON ABSORBANT
    code 32
  • food prep surfaces dirty
    Official wording: Food And Non-Food Contact Equipment Utensils Clean, Free Of Abrasive Detergents
    Inspector note: GREASE ON FILTERS AND HOOD ABOVE THE BBQ AND BRICK OVEN FIRST FLOOR, NEED TO CLEAN AND MAINTAIN. EXTERIOR OF DISH MACHINE DIRTY. MUST CLEAN. SURROUND OF BRICK OVEN NOT CLEAN. MUST REMOVE ALL DEBRIS
    code 33
  • Floors: Constructed Per Code, Cleaned, Good Repair, Coving Installed, Dust-Less Cleaning Methods Used
    Inspector note: FLOOR NOT CLEAN THROUGH-OUT, INCLUDING BASEMENT. UNEVEN AND POROUS MATERIAL BY THE FRONT PREP AREA (BBQ/BRICK OVEN). NEED TO KEEP FLOOR CLEAN AND IN GOOD REPAIR IN DINING/CLASS ROOM FIRST LEVEL PREP AREA. SURFACE MUST BE SMOOTH, CLEANABLE AND NON-ABSORBENT SURFACE. REMOVE FOAM SEALANT UNDER 3 COMPARTMENT SINK AND AT STAIRS AND REPAIR TO BE SMOOTH AND EASILY CLEANABLE.
    code 34
  • Walls, Ceilings, Attached Equipment Constructed Per Code: Good Repair, Surfaces Clean And Dust-Less Cleaning Methods
    Inspector note: CEILING IN REAR PREP AREA IN POOR REPAIR, HOLES AND OPENINGS. MUST SMOOTHLY SEAL ALL OPENINGS.
    code 35
  • pests in the house
    Official wording: Ventilation: Rooms And Equipment Vented As Required: Plumbing: Installed And Maintained
    Inspector note: PROVIDE WORKING VENTILATION AT ALL HOODS ABOVE COOKING EQUIPMENT. ADDITIONAL STOPPER IS NEEDED AT THREE COMPARTMENT SINK. NO BACK FLOW PREVENTION DEVICES ON HOSE BIB IN BASEMENT OR UNDER REAR PREP AREA EXPOSED HAND SINK. MUST INSTALL.
    code 38
  • grimy wiping cloths
    Official wording: Premises Maintained Free Of Litter, Unnecessary Articles, Cleaning Equipment Properly Stored
    Inspector note: UNORGANIZED BASEMENT AREAS, MUST REORGANIZE AND ELEVATE ITEMS 6" ABOVE THE FLOOR. REMOVE ALL UNNECESSARY ITEMS, INCLUDING PROPANE TANKS, TO PREVENT PEST HARBORAGE AND TO FACILITATE CLEANING.
    code 41

What changed since the previous inspection?

Compared with Fail on May 26, 2017: 6 findings recurred. 2 previous findings did not recur.