Burger King

March 19, 2013 · Fail
🪳cooked
  • official resultFail
  • resultFail
  • inspection typeLicense
  • failed findings9
  • critical findings1

← Back to the current restaurant page

Failed findings

  • food from a questionable sourcecritical
    Official wording: Adequate Number, Convenient, Accessible, Designed, And Maintained
    Inspector note: AN EXPOSED HAND SINK MUST BE INSTALLED BY THE UTENSIL WASHING AREA/THREE COMPARTMENT SINK. MUST FOLLOW CITY PLUMBING CODE.
    code 11Priority
  • Dish Washing Facilities: Properly Designed, Constructed, Maintained, Installed, Located And Operated
    Inspector note: WASTE WATER LINE IS DRAINING INSIDE THE THREE COMPARTMENT SINKS, MUST BE PROPERLY CONNECTED SUCH THAT IT DRAINS INTO A FLOOR DRAIN.
    code 24
  • Food And Non-Food Contact Surfaces Properly Designed, Constructed And Maintained
    Inspector note: OBSERVED RUSTY SHELVES IN REAR STORAGE AREA, INSTRUCTED TO PAINT OR REPLACE. BROKEN RUBBER GASKET INSIDE THE DOOR OF WALK-IN COOLER, MUST BE REPLACE. ALSO REPLACE RUBBER GASKET INSIDE THE ICE MACHINE. MIDDLE CABINET UNDER THE FRONT COUNTER TOP IN POOR REPAIR,SURFACE MUST BE SMOOTH, CLEANABLE AND NON-ABSORBENT MATERIAL.
    code 32
  • food prep surfaces dirty
    Official wording: Food And Non-Food Contact Equipment Utensils Clean, Free Of Abrasive Detergents
    Inspector note: REMOVE MINERAL BUILD-UP AND BLACK SUBSTANCE FROM INTERIOR PANELS OF ICE MACHINE,TOP AND BOTTOM OF THE UNIT. REMOVE DEBRIS UNDER THE UNIT WERE BREAD IS STORED.
    code 33
  • Floors: Constructed Per Code, Cleaned, Good Repair, Coving Installed, Dust-Less Cleaning Methods Used
    Inspector note: REPAIR /REPLACE BROKEN /MISSING BASE BOARD THROUGHOUT THE PREMISES. GREASE AND DEBRIS BUILD-UP ON FLOORS UNDER FRONT LINE AND UNDER AND AROUND WASTE OIL RECYLCING TANK. ICE BUILD-UP ON FLOOR IN WALK-IN FREEZER. RUSTY FLOOR INSIDE INSIDE WALK-IN COOLER. MUST REFINISH OR RAPLACE FLOOR.
    code 34
  • Walls, Ceilings, Attached Equipment Constructed Per Code: Good Repair, Surfaces Clean And Dust-Less Cleaning Methods
    Inspector note: REMOVE PEELING PAINT IN REAR STORAGE AREA,WALL IN NEED OF PAINT SAID AREA. NEED TO CLEAN WALL TILES(GRIME) AROUND THE RECYCLE WASTE OIL TANK,BY THE WALK-IN COOLER. REPLACE BROKEN WALL TILE UNDER THE THREE COMPARTMENT SINK AND WEST WALL,SEAL HOLES ON CEILING AND WALLS THROUGHOUT THE PREMISES
    code 35
  • thermometers missing
    Official wording: Lighting: Required Minimum Foot-Candles Of Light Provided, Fixtures Shielded
    Inspector note: REPLACE BROKEN LIGHT SHIELD IN PREP AREA.
    code 36
  • pests in the house
    Official wording: Ventilation: Rooms And Equipment Vented As Required: Plumbing: Installed And Maintained
    Inspector note: STOPPER IS NEEDED AT THREE COMPARTMENT SINK. REPAIR LEAKING PIPE UNDER THE TWO COMPARTMENT SINKS. REPAIR LEAKING FAUCET AT THREE COMPARTMENT SINK. PROVIDE A BACK FLOW PREVENTION DEVICE AT FAUCET BY THE MOP SINK (USED FOR POWER WASHING).
    code 38
  • No Smoking Regulations
    Inspector note: 'NO SMOKING' SIGNS NOT POSTED AT ENTRANCES. MUST POST SIGNS AT ALL ENTRANCES AND OTHER AREAS WHERE SMOKING IS PROHIBITED.
    code 70

Browse this restaurant's inspections

About this record

This record comes from Chicago Department of Public Health. Cooked keeps the official result and wording separate from its plain-English explanation so you can verify what the inspector actually published.

Source: Chicago Data Portal.

official city health-inspection data · no account, no sign-up