June 3, 2016 · Fail
🪳cooked
  • official resultFail
  • resultFail
  • inspection typeCanvass
  • failed findings6
  • critical findings1

← Back to the current restaurant page

Failed findings

  • handwashing sink blocked or barecritical
    Official wording: Sewage And Waste Water Disposal, No Back Siphonage, Cross Connection And/Or Back Flow
    Inspector note: NOTED WASTE WATER BACKING UP FROM THE KITCHEN FLOOR DRAIN WHEN WATER IS OPENED AT THE ONE COMPARTMENT SINK OR THE HAND WASH SINK ON THE FIRST FLOOR. STANDING WASTE WATER AND FOUL SEWAGE SMELL IN FOOD PREP AREA. CRITICAL VIOLATION #7-38-030. MUST REPAIR PLUMBING. WASH, RINSE AND SANITIZE FLOOR AND SURFACES.
    code 10Priority
  • toxic chemicals mishandled
    Official wording: Previous Minor Violation(S) Corrected 7-42-090
    Inspector note: NOTED THE FOLLOWING PREVIOUS MINOR VIOLATIONS FROM REPORT #1441935 DATED 6/12/2015 NOT CORRECTED:-35)OBSERVED A FEW WATER DAMAGED CEILING TILES ABOVE COOKING EQUIPMENT IN BASEMENT FOOD PREPARATION AREA AND IN REAR AREA ABOVE MOP SINK, MUST REPAIR AND MAINTAIN.#38)LEAKY FAUCET BASE AT THE 3-COMPARTMENT SINK IN BASEMENT. MUST REPAIR AND MAINTAIN. OBSERVED NO BACK FLOW PREVENTION DEVICE AT THE MOP SINK IN BASEMENT. MUST PROVIDE. #41)INSTRUCTED TO CLEAN AND REMOVE UNNECESSARY ARTICLES AND CLUTTER IN REAR OUTSIDE AREA (NEXT TO REAR EXIT DOOR) TO PREVENT PEST HARBORAGE. MUST CORRECT ALL ABOVE VIOLATIONS. SERIOUS VIOLATION #7-42-090
    code 29
  • Walls, Ceilings, Attached Equipment Constructed Per Code: Good Repair, Surfaces Clean And Dust-Less Cleaning Methods
    Inspector note: ACCUMULATED GREASE IN FILTERS AND HOOD AT FIRST FLOOR COOKING AREA. MUST CLEAN AND MAINTAIN SAME.
    code 35
  • food improperly labeled
    Official wording: Toilet Room Doors Self Closing: Dressing Rooms With Lockers Provided: Complete Separation From Living/Sleeping Quarters
    Inspector note: BASEMENT TOILET ROOM DOOR, IN A PREP AREA, IS NOT SELF-CLOSING. MUST INSTALL WORKING SELF-CLOSING DEVICE.
    code 37
  • pests in the house
    Official wording: Ventilation: Rooms And Equipment Vented As Required: Plumbing: Installed And Maintained
    Inspector note: 2 OF THE 10 BURNERS OF BASEMENT RANGE NOT UNDER HOOD. MUST INSTALL LARGER HOOD OR SMALLER RANGE. NO VISIBLE BACKFLOW PREVENTION DEVICE AT WATER SUPPLY TO BASEMENT ICE MACHINE. MUST INSTALL. NO GREASETRAP AT ONE OF THE 3 COMPARTMENT SINKS IN BASEMENT, FOOD DEBRIS IN SINK. MUST INSTALL GREASETRAP. SODA GUN DRAIN LINE DISPENSES IN BAR EXPOSED HAND SINK. MUST REROUTE DRAIN LINE.
    code 38
  • grimy wiping cloths
    Official wording: Premises Maintained Free Of Litter, Unnecessary Articles, Cleaning Equipment Properly Stored
    Inspector note: 1ST FLOOR REAR STORAGE ROOM IS CLUTTERED AND UNORGANIZED. MUST CLEAN, ORGANIZE AND MAINTAIN ROOM TO PREVENT PEST HARBORAGE.
    code 41

What changed since the previous inspection?

Compared with Pass w/ Conditions on June 19, 2015: 3 findings appeared for the first time. 3 findings recurred. 4 previous findings did not recur.