✓ No failed findings were recorded; 5 code checks were marked passed.

← Back to the current restaurant page

Checks marked passed

  • Clean-up of Vomiting and Diarrheal Events (Pf)
    Inspector note: No V&D Kit. Provide.
    code 590.002/2-501.11-PF** · serious findingstatus: Pass
  • Mechanical Warewashing Equipment Hot Water Sanitization Temperatures (Pf)
    Inspector note: 3rd floor high temperature dish machine in banquet dish room is not reaching 180F. Repair. Alternative means to sanitize equipment in ground floor 3 compartment sink.
    code 590.004/4-501.112-PF** · serious findingstatus: Pass
  • Surface Characteristics-Indoor Areas (C)
    Inspector note: Pipe in dish room with exposed insulation. Seal. Damaged ceiling tile. Replace.
    code 590.006/6-101.11-C* · lower-severity findingstatus: Pass
  • Light Bulbs Protective Shielding (C)
    Inspector note: Broken light shield in ceiling above dish machine. replace.
    code 590.006/6-202.11-C* · lower-severity findingstatus: Pass
  • Heating Ventilation Air Conditioning System Vents (C)
    Inspector note: Clean HVAC vent in ceiling above dish machine
    code 590.006/6-202.12-C* · lower-severity findingstatus: Pass

What changed since the previous inspection?

Compared with Fail on July 10, 2023: 5 previous findings did not recur.

Browse this restaurant's inspections

About this record

This record comes from Boston Inspectional Services, Health Division. Cooked keeps the official result and wording separate from its plain-English explanation so you can verify what the inspector actually published.

Source: Analyze Boston.

official city health-inspection data · no account, no sign-up