Tico

August 28, 2017 · Pass
😇clean
  • official resultPass
  • resultPass
  • inspection typeEating & Drinking
  • failed findings0
  • critical findings0
✓ No failed findings were recorded; 6 code checks were marked passed.

← Back to the current restaurant page

Checks marked passed

  • Food Contact Surfaces Cleancritical
    Inspector note: Interior of ice machine soiled.Clean to remove all soils. Maintain cleaning with more frequency PIC instructed staff to discontinue using machine.
    code 20-4-703.11*** · critical food-safety factorstatus: Pass
  • Separation/Sanitizer Criteriacritical
    Inspector note: Low temp machine not reading sanitizer.Repair.Maintain sanitizer 50PPM PIC to discontinue using machine until repaired
    code 41-7-201/04.11*** · critical food-safety factorstatus: Pass
  • Insects Rodents Animals
    Inspector note: Visible fruit flies in bakery/mop sink areas.PIC to address with pest control company. Provide up to date IPM report upon re-inspection.
    code 35-6-501.111/.115** · serious findingstatus: Pass
  • Wash Rinse Water Clean Proper Temperature.
    Inspector note: Low temp machine rinse reading 70F.Repair.Maintain low temp rinse reading 120-140F or pe manufactures instructions. High temp kitchen machine rinse reading 175F.Repair.Maintain 180-194F or per manufactures instructions.
    code 19-4-501.18-.110* · lower-severity findingstatus: Pass
  • Non-Food Contact Surfaces Clean
    Inspector note: Ice machine vents observed with visible dust.Clean to remove Clean vent covers to remove dust build up in keg walk in.
    code 23-4-602.13* · lower-severity findingstatus: Pass
  • Installed and Maintained
    Inspector note: Hot water at all handwash sinks reading 80F.Repair.Maintain hot water 110F minimum to ensure proper handwashing. PIC has called a plumber to address the issue. Upon re-inspection.PIC has provided plumber & national grid reports.PIC states that a company rep from Rheem concerning the hot water heater will be on site today(8.18.17) to assess the condition of the hot water unit. At the time of re-inspection Hot water temped at 117F. PIC states the hot water heater is currently on a 12 hour factory reset and will be monitored by staff.
    code 29-5-201/02.11* · lower-severity findingstatus: Pass

What changed since the previous inspection?

Compared with Fail on August 18, 2017: 6 previous findings did not recur.

Browse this restaurant's inspections

About this record

This record comes from Boston Inspectional Services, Health Division. Cooked keeps the official result and wording separate from its plain-English explanation so you can verify what the inspector actually published.

Source: Analyze Boston.

official city health-inspection data · no account, no sign-up