China Garden

August 1, 2013 · Fail
😬mid
  • official resultFail
  • resultFail
  • inspection typeEating & Drinking w/ Take Out
  • failed findings4
  • critical findings0

← Back to the current restaurant page

Failed findings

  • Cross Connection Back Siphonage Backflow
    Inspector note: Spray arm of 3 bay sink hangs below the fill line. Discotinue and ensure that the spray arm hangs premanently above the fill line.
    code 30-5-203.14** · serious findingstatus: Fail
  • Non-Food Contact Surfaces
    Inspector note: Small deli cooler with an elevated temperature of 47F. Discontinue use until unit is able to maintain a temperature of below 41F. Restaurant is not currently open and operating. • Gaskets around small walk-in coolers damaged. Replace. Condensation drain of walk-in cooler not attached and observed draining into a pan on shelf. Reconnect to allow for proper drainage.
    code 15-4-202.16* · lower-severity findingstatus: Fail
  • Test Kit Provided
    Inspector note: Wrong test kit being used for chlorine sanitizer. Provide correct test kit for sanitizer being used on site.
    code 17-4-302.14* · lower-severity findingstatus: Fail
  • Mop Sink not Provided
    Inspector note: No mop sink evident at the time of the initial inspection. Provide an enclosed mop sink.
    code 42-5-203.13* · lower-severity findingstatus: Fail

Checks marked passed

  • Food Protection
    Inspector note: Hand sink located directly next to preparation table with no splash guard. Provide a splash guard or relocate.
    code 08-3-305-307.11* · lower-severity findingstatus: Pass
  • Food Utensil Storage
    Inspector note: Knives observed being stored in between preparation table and deli style cooler. Discontinue and store all knives in a clean and sanitized area.
    code 10-3-304.12* · lower-severity findingstatus: Pass
  • Food Contact Surfaces Design
    Inspector note: Plastic containers being used to dispense out of bulk food containers. Discotninue and use handled scoops to prevent contamination from hands.
    code 14-4-202.11* · lower-severity findingstatus: Pass
  • Non-Food Contact Surfaces Clean
    Inspector note: Drying racks above 3 bay sink visibly soiled. Clean to remove.
    code 23-4-602.13* · lower-severity findingstatus: Pass

What changed since the previous inspection?

Compared with Fail on July 29, 2013: 4 findings recurred. 4 previous findings did not recur.

Browse this restaurant's inspections

About this record

This record comes from Boston Inspectional Services, Health Division. Cooked keeps the official result and wording separate from its plain-English explanation so you can verify what the inspector actually published.

Source: Analyze Boston.

official city health-inspection data · no account, no sign-up